Heavy-Duty 8W/ft Self-Regulating Roof & Gutter Heat Cable (KPSR)
YeloDeer KPSR is a thicker 120V gutter heat tape for customers who want higher output and a more rugged cable than YeloDeer's lighter 6W/ft roof de-icing kit.
8W/ft Output Higher nominal output than the 6W/ft kit.
Thicker Cable Approx. 0.43 × 0.21 in / 10.98 × 5.4 mm.
IP67 Outdoor construction for properly installed winter applications.
Why Choose This Version?

More Heating Output 8W/ft versus 6W/ft on the lighter kit. Choose this version when higher-output roof and gutter heating is the priority.
More Substantial Cable Body The larger cable profile provides a more heavy-duty physical design for customers who prefer a thicker roof de-icing cable.
Longer Finished Lengths Options extend up to 130 ft for larger roof, gutter, and downspout layouts.
Heavy-Duty Clip System Compatible full-size YeloDeer roof clips are larger and more robust than the basic clips supplied with the 6W/ft kit.
8W Heavy-Duty Cable or 6W Kit?
|
KPSR 8W Heavy-Duty Cable |
6W Roof De-Icing Kit |
| Heating Output |
8W/ft |
6W/ft |
| Cable Body |
Thicker, more substantial profile |
Thinner, lighter profile |
| Roof Clips |
Full-size clips sold separately |
Basic clips and spacers included |
| Length Range |
6–130 ft |
15–80 ft |
| Choose It When |
You prioritize higher output, heavier-duty construction, larger mounting hardware, or longer finished lengths. |
You want a simpler, more economical kit with mounting accessories already included. |
Want the lighter cable with basic roof clips and spacers included? Compare the YeloDeer 6W/ft Self-Regulating Roof & Gutter Heat Cable Kit →
Roof Clips Are Sold Separately
Add roof clips when the cable will be mounted on the roof surface.
This thicker cable uses YeloDeer's full-size aluminum roof clip system. Choose the mounting style according to the roof material and installation method.
RC-NF Nail-Free Clips For compatible asphalt shingles where a non-penetrating slide-on installation is preferred.
RC-NG Nail / Glue Clips For compatible installations using an approved nail, screw, adhesive, or combined mounting method.
Choosing a clip option: Nail-Free Roof Clips (RC-NF) are an alternative to Nail/Glue Roof Clips (RC-NG) for compatible asphalt shingles only. They slide onto the shingle edge without nails, screws, or adhesive and are not suitable for metal, slate, tile, cedar shake, or membrane roofs.
Clip options include only the selected quantity of clips, not heating cable. To order both, add your cable length and clip pack to the cart separately.
Choose Full-Size Roof Heat Cable Clips →
Automatic Control Is Optional
Self-regulating does not mean automatic ON/OFF.
The cable adjusts heat output as temperature changes, but it does not detect snow or moisture by itself. Add a compatible roof de-icing controller when automatic temperature-and-moisture control is preferred.
View the YeloDeer Roof De-Icing Controller →
Before You Order
Measure the complete heating route Include gutter and downspout length Select a factory-finished cable length Add roof clips when roof mounting is required Confirm the 6 ft power cord can reach the power location Decide whether automatic control is needed
Do not treat this as a normal field-cut cable.
For most installations, choose the closest factory-finished length and keep the factory power connection and end termination intact. If exact custom lengths are required, use a bulk cut-to-length roof heat trace system with the correct termination accessories.
Need a custom professional system? See the YeloDeer Bulk Cut-to-Length Roof & Pipe Heat Trace Cable →



Recommended Applications

Roof Edges & Eaves
Roof Edges Eaves Overhangs Ice-Prone Areas
Gutters & Downspouts
Gutters Downspouts Frozen Drainage Icicle Areas
Complex Roof Details
Valleys Dormers Skylight Areas Drainage Paths
Common Roof Surfaces
Asphalt Shingles Metal Roofs Standing Seam Compatible Roofing
How Roof & Gutter Heat Cable Helps
This self-regulating roof heat cable helps maintain a meltwater path through ice-prone roof edges, gutters, and downspouts. Keeping the drainage route open can help reduce recurring roof-edge ice buildup, frozen gutters, and blocked downspouts.
Designed for prevention and drainage. Roof de-icing cable is not intended to melt all snow across the entire roof surface or rapidly remove a large ice dam that has already formed.
Compatible Roof & Gutter Materials
Asphalt shingles Synthetic roofing Metal roofs Standing seam metal roofs Ceramic tile Slate and stone roofs Metal gutters Plastic gutters
Use mounting hardware and attachment methods that are appropriate for the actual roofing material. Do not damage shingles, membranes, flashing, gutters, or the heating cable during installation.
When Not to Use This Product
- To rapidly remove a large existing ice dam
- To melt heavy snow across the entire roof surface
- For internal pipe heating
- For long-term submersion
- For installations requiring custom field branching or exact cut lengths
- Where suitable roof-safe mounting hardware cannot be used
- Where the plug or outlet may remain in standing water
- Where the cable may be crushed, punctured, sharply bent, or damaged by improper fasteners
Product Specifications
| Model |
KPSR |
| Product Type |
Heavy-duty self-regulating roof and gutter de-icing cable |
| Primary Application |
Roof edge, gutter, downspout, and ice-dam prevention layouts |
| Voltage |
120V AC |
| Nominal Heating Output |
8W/ft |
| Heating Technology |
Self-regulating heating cable |
| Cable Size |
Approx. 0.43 × 0.21 in / 10.98 × 5.4 mm |
| Cable Construction |
Rugged outdoor design with tinned copper core |
| Waterproof Rating |
IP67 |
| Maximum Exposure Temperature |
150°F / 65°C |
| Power Cord Length |
6 ft |
| Plug |
Lighted plug |
| Finished Heating Lengths |
6, 12, 18, 24, 30, 36, 50, 65, 75, 85, 100, 110, 120, and 130 ft |
| Roof Clips |
Not included with the heating cable; compatible full-size clips sold separately |
| Automatic Snow / Moisture Control |
Not built in; compatible roof de-icing controller sold separately |
| Normal Length Selection |
Select the appropriate factory-finished length; do not casually cut or modify the factory assembly |
The full-size YeloDeer roof clips support compatible heating cable profiles up to approximately 0.55 × 0.31 in / 14 × 8 mm. Confirm the cable profile and roof mounting method before ordering clips.
Installation
Plan the Complete Cable Route
Roof-edge zigzag pattern Gutter length Downspout height Valleys and problem areas Roof clip quantity Outlet location 6 ft power-cord reach Controller location if used
Do not calculate cable length from gutter length alone. Include every section where the cable must travel to maintain the planned meltwater path.
Basic Installation Sequence
- Inspect the roof, gutters, downspouts, heating cable, plug, and mounting locations.
- Identify the areas where ice buildup normally blocks drainage.
- Measure the complete roof-edge, gutter, and downspout cable route.
- Select compatible full-size roof clips when roof mounting is required.
- Install the clips according to the roof material and approved mounting method.
- Position the cable in the planned roof-edge pattern.
- Continue the cable through the gutter and downspout where heating is required.
- Secure the cable without crushing, puncturing, scraping, or sharply bending it.
- Keep the plug and electrical connection protected from standing water.
- Connect the system to a suitable protected 120V power source.
- Install and configure the compatible roof controller if automatic operation is required.
- Inspect the complete system before winter and after severe weather.



Roof Clip Selection
RC-NF Nail-Free Slides onto compatible asphalt shingles without nails, screws, or adhesive.
RC-NG Nail / Glue Supports approved nail, screw, adhesive, or combined mounting methods depending on the roofing system.
Review Roof Clip Sizes & Mounting Options →
Installation Safety
- Install before heavy snow or ice buildup whenever possible.
- Do not work on an icy, wet, unstable, steep, or otherwise unsafe roof.
- Use appropriate roof-access and fall-protection equipment.
- Do not use staples, sharp wire, or other fasteners that can damage the cable jacket.
- Do not damage shingles, membranes, flashing, or gutters while mounting the cable.
- Do not energize a visibly damaged cable.
- Use professional installation for high, steep, metal, or complex roof layouts when the work is outside your experience.
Review the YeloDeer Installation Guide →
FAQ
How is this different from the 6W/ft roof de-icing kit?
This is the heavier-duty option. It provides 8W/ft nominal output and uses a thicker cable body. Compatible full-size roof clips are sold separately. The 6W/ft version uses a thinner cable and includes basic clips and spacers, making it a simpler and more economical kit for customers who do not need the heavier-duty configuration.
Why does this version cost more even though roof clips are sold separately?
The additional cost is concentrated in the heating cable: higher 8W/ft output, a thicker cable body, IP67 outdoor construction, a lighted plug, and finished lengths up to 130 ft. The separate full-size clip system also lets you select larger, more robust mounting hardware for the actual roof and installation method.
Are roof clips included with the cable?
No. Add compatible full-size YeloDeer roof clips when the installation requires mounting on the roof surface. The clip product is available in nail-free and nail / glue mounting styles.
Does self-regulating heat trace need a thermostat?
The cable does not need a thermostat in order to self-regulate. Self-regulating means its heat output changes with temperature. However, the cable does not automatically sense snow or moisture. A compatible roof de-icing controller can provide automatic temperature-and-moisture-based operation.
Can this gutter heat tape be installed in downspouts?
Yes. Gutters and downspouts are part of the intended roof de-icing application. Plan enough cable to maintain the meltwater path through the gutter and downspout rather than heating only the roof edge.
Can it be used on metal roofs and asphalt shingles?
Yes. It can be used on compatible metal and asphalt roofing surfaces when installed with appropriate roof-safe mounting hardware. Select the clip and attachment method according to the actual roofing material.
Can I cut the factory-finished cable shorter?
For normal plug-in installations, select the closest factory-finished length instead of cutting or modifying the cable. Correct field termination requires suitable components and termination knowledge. Choose the YeloDeer bulk cut-to-length roof heat trace cable when exact custom lengths are required.
Will this roof heat cable remove an ice dam that already exists?
It is designed mainly to help prevent ice dams and maintain meltwater drainage paths. It is not intended to rapidly remove a large existing ice dam or clear heavy snow from the entire roof.
Guides

Measure Before Ordering
Calculate the complete heating route before selecting a cable length. Include the roof-edge pattern, gutter run, downspout, valleys, problem areas, and the route toward the power source.
Match the Clip to the Roof
Choose nail-free clips only for compatible asphalt shingles. Use the appropriate approved mounting method for metal roofs, membranes, and other roofing systems.
Review Full-Size Roof Heat Cable Clips →
Consider Automatic Winter Control
Self-regulating cable changes heat output but does not independently detect snow or moisture. A compatible controller can reduce manual plugging and provide more automatic seasonal operation.
View the Roof De-Icing Controller →