Aluminum Roof Heat Cable Clips for Roof & Gutter De-Icing Cable Installation
YeloDeer roof heat cable clips are designed to securely position self-regulating roof and gutter de-icing cables along roof edges, eaves, valleys, dormers and other ice-prone areas.
Available in two mounting styles, these aluminum roof cable clips help homeowners, roofers and contractors create a reliable heating cable layout based on different roofing materials and installation requirements.
Choose RC-NF Nail-Free for compatible asphalt shingle roofs where a non-penetrating installation is preferred, or choose RC-NG Nail / Glue when the project requires flexible mounting using approved nails, screws, adhesive or combined methods.
Quick Fit Snapshot
Two Mounting Styles Choose nail-free slide-on installation or nail / screw / adhesive mounting according to your roof type.
Full-Size Cable Compatible Supports common roof heating cable profiles up to 0.55 × 0.31 in (14 × 8 mm).
Aluminum Alloy Construction Designed for outdoor roof de-icing applications and winter weather exposure.
DIY & Professional Use Suitable for homeowners, roofers and contractors when properly installed.
Choose Your Clip Type
RC-NF Nail-Free
No Nails No Screws No Adhesive Asphalt Shingles
Designed for compatible asphalt shingle roofs. The clip slides onto the shingle edge and secures mechanically without roof penetration.
RC-NG Nail / Glue
Nail Mounting Screw Mounting Adhesive Mounting Flexible Installation
Designed for projects requiring multiple mounting options on compatible roofing surfaces.
Designed for Common Full-Size Roof Heating Cable
Both RC-NF and RC-NG roof cable clips support heating cables with a maximum profile of: 0.55 × 0.31 in (14 × 8 mm).
This size range is intended to fit many commonly used full-size self-regulating roof heat cable profiles on the market. Always measure your actual cable width and height before ordering.
Compatibility by Cable Size, Not Brand
The 0.55 × 0.31 in (14 × 8 mm) maximum profile is intended to fit many commonly used full-size self-regulating roof heat cable profiles, including compatible models from nVent RAYCHEM, Thermon, EasyHeat, Warmup, WarmlyYours, Heat-Line, Drexan, BriskHeat, Frost King and YeloDeer.
Compatibility can vary by model even within the same brand. Measure the cable’s actual width and height and confirm that the cable manufacturer permits clip mounting before installation.
These clips are compatible with YeloDeer roof de-icing cables, including:
Key Benefits
Secure Cable Positioning Keeps roof heating cable organized along eaves, roof edges, valleys and other planned heating routes.
Flexible Installation Options Choose nail-free installation or traditional mounting methods depending on your roof requirements.
Weather-Resistant Aluminum Aluminum alloy construction provides reliable outdoor performance in winter conditions.
Compatible Cable Profile Designed for common full-size self-regulating roof heat cable.
Multiple Pack Sizes Available options support residential and professional projects.
Complete System Component Works together with YeloDeer roof de-icing cables for complete winter protection solutions.
Compatible YeloDeer Roof De-Icing Cables
Build a complete roof de-icing system with compatible YeloDeer self-regulating heating cables:
Compatibility Note: These clips only support cable mounting. Always confirm cable dimensions and follow the heating cable manufacturer's installation instructions.
Recommended Applications
Select the correct roof heat cable clip according to your roofing material, mounting method and heating cable installation requirements.
Asphalt Shingle Roofs
Three-Tab Shingles Architectural Shingles Residential Roofs
Roof Edges & Eaves
Ice-Prone Areas Gutter Lines Meltwater Paths
Roof Valleys & Dormers
Roof Valleys Dormer Areas Complex Layouts
Professional Installations
Roofers Contractors Winter Protection
RC-NF Nail-Free Application
Use RC-NF For Compatible three-tab and architectural asphalt shingles where a non-penetrating mounting method is preferred.
Do Not Use RC-NF For Metal roofs, slate, tile, cedar shake or membrane roofing systems.
RC-NG Nail / Glue Application
Use RC-NG For Projects requiring approved adhesive, nail, screw or combined mounting methods.
Important Requirement The selected adhesive, fastener and sealant must match the roofing material and outdoor conditions.
Roof Compatibility Reference
| Roof Material |
RC-NF Nail-Free |
RC-NG Nail / Glue |
| Three-Tab Asphalt Shingles |
Recommended |
Compatible with approved mounting method |
| Architectural Asphalt Shingles |
Recommended within grip range |
Compatible |
| Metal Roof / Flashing |
Not Recommended |
Use approved mounting method |
| EPDM / TPO / PVC Membrane |
Not Recommended |
Use membrane-approved bonding method |
| Cedar / Wood Shake |
Not Recommended |
Use approved fastening and sealing method |
Product Specification Comparison
| Specification |
RC-NF Nail-Free |
RC-NG Nail / Glue |
| Product Type |
Nail-free roof heat cable clip |
Nail / Glue roof heat cable clip |
| Main Application |
Securing roof and gutter de-icing cable on compatible asphalt shingles |
Securing roof and gutter de-icing cable using approved mounting methods |
| Maximum Cable Profile |
0.55 × 0.31 in (14 × 8 mm) |
0.55 × 0.31 in (14 × 8 mm) |
| Compatible Cable Type |
Full-size self-regulating roof heat cable and other compatible heating cables within the stated profile range |
| Material |
Aluminum Alloy |
| Measured Metal Thickness |
1.0 mm |
1.2 mm |
| Mounting Method |
Slide-on mechanical grip |
Nail, screw, adhesive or combined mounting |
| Roof Penetration |
None |
Depends on selected mounting method |
| Maximum Roofing Material Grip |
Approx. 0.38 in (9.7 mm) |
Not applicable |
| Nails / Screws Required |
No |
Depending on selected mounting method |
| Adhesive Required |
No |
Depending on selected mounting method |
| Available Pack Sizes |
10 / 25 / 50 Pcs |
20 / 40 / 60 Pcs |
| Heating Cable Included |
No. Clips only. |
| Package Contents |
Selected quantity of aluminum roof heat cable clips only. |
| Not Included |
Heating cable, nails, screws, adhesive, roofing sealant and installation tools. |
Cable Measurement Note
The maximum cable profile refers to the approximate heating cable width × height.
Cable size may vary depending on model, manufacturer, voltage, wattage and jacket construction. Always measure the actual heating cable before ordering.
Do not force an oversized cable into a smaller clip, as this may damage the clip or heating cable jacket.
Clip Quantity Reference
| Clip Type |
Pack Size |
Reference Coverage |
| RC-NG Nail / Glue |
20 Pcs |
Approx. 10 ft of roof edge |
| 40 Pcs |
Approx. 20 ft of roof edge |
| 60 Pcs |
Approx. 30 ft of roof edge |
| RC-NF Nail-Free |
10 Pcs |
Approx. 7.5 ft of roof edge |
| 25 Pcs |
Approx. 18.75 ft of roof edge |
| 50 Pcs |
Approx. 37.5 ft of roof edge |
Planning Note: Coverage values are conservative references only. Actual clip requirements depend on roof geometry, eaves, valleys, dormers, corners, wind exposure and the heating cable manufacturer's recommended spacing.
Installation Overview
Roof heat cable clips are designed to secure roof and gutter de-icing cables in the planned installation pattern. Before installation, confirm the heating cable layout, roof condition and selected clip type.
Important: Disconnect the heating cable from power before installation, removal or adjustment.
Before Installing
Confirm the heating cable route Select the correct clip type Verify roof material compatibility Measure heating cable profile Confirm mounting method requirements Use appropriate roof safety equipment Follow heating cable manufacturer's instructions Do not install on damaged roofing materials
RC-NF Nail-Free Installation
-
Plan the Cable Layout
Determine the heating cable route along eaves, roof edges, valleys or other ice-prone areas according to the heating cable manufacturer's layout requirements.
-
Install the Clip onto the Shingle
Slide the RC-NF clip onto the lower edge of the compatible asphalt shingle. Ensure the clip is fully seated and securely engaged.
-
Insert the Heating Cable
Place the roof heating cable into the cable-retaining hook.
-
Secure the Cable
Gently close the retaining hook around the heating cable. Do not crush, deform or damage the cable jacket.
-
Final Inspection
Confirm that every clip is secure, the cable route is correct and the cable is not under excessive tension.
RC-NG Nail / Glue Installation
RC-NG provides flexible mounting options. Select the installation method according to the roofing material and approved mounting requirements.
Adhesive Mounting Use an outdoor roofing adhesive or adhesive-sealant approved for aluminum and the exact roofing substrate. Allow the adhesive to fully cure before installing or loading the heating cable.
Nail / Screw Mounting Use fasteners approved for the roofing system. Seal roof penetrations with compatible roofing sealant when required.
Combined Mounting Some projects may require both fasteners and adhesive or sealing materials depending on roofing requirements.
Installation Warnings
- Do not install clips on loose, damaged or brittle roofing materials.
- Do not use adhesive, fasteners or sealants that are incompatible with the roof surface.
- Do not crush, cut or puncture the heating cable jacket.
- Do not pull the heating cable tightly between clips.
- Allow adhesive and sealant to cure completely before energizing the system.
- Follow applicable electrical, roofing and building requirements.
Guide 1: Choose the Right Clip
Selecting the correct roof heat cable clip depends on your roofing material, heating cable size and required mounting method.
Identify your roof surface before ordering
Choose RC-NF for compatible asphalt shingles without roof penetration
Choose RC-NG when adhesive, nails, screws or combined mounting is required
Confirm heating cable profile does not exceed 0.55 × 0.31 in (14 × 8 mm)
For RC-NF, confirm shingle thickness is within approximately 0.38 in (9.7 mm) grip range
Follow both roofing manufacturer and heating cable manufacturer requirements
RC-NF vs RC-NG Selection Guide
| Question |
Recommended Choice |
|
Do you want installation without nails, screws or adhesive?
|
Choose RC-NF Nail-Free for compatible asphalt shingle roofs.
|
|
Does your roof require adhesive or fastened mounting?
|
Choose RC-NG Nail / Glue for approved mounting methods.
|
|
Are you installing on metal, membrane or other non-shingle surfaces?
|
Use RC-NG with a suitable approved attachment method.
|
Guide 2: Estimate the Pack Size
Calculate clip quantity based on the roof-edge sections where the heating cable will be mounted. Do not calculate based on total heating cable length.
| Clip Type |
Reference Coverage |
|
RC-NG Nail / Glue
|
Approximately 20 clips per 10 ft of roof edge
|
|
RC-NF Nail-Free
|
Approximately 10 clips per 7.5 ft of roof edge
|
RC-NG 40 Pcs ≈ 20 ft roof-edge planning reference
RC-NG 60 Pcs ≈ 30 ft roof-edge planning reference
RC-NF 25 Pcs ≈ 18.75 ft roof-edge planning reference
RC-NF 50 Pcs ≈ 37.5 ft roof-edge planning reference
Add extra clips for valleys, dormers and corners
Choose the next larger pack size if your requirement falls between options
Planning Note: These coverage values are conservative references only. The heating cable manufacturer's required layout and spacing always take priority.
Guide 3: Choose an Adhesive for RC-NG
When using RC-NG with adhesive mounting, the adhesive must bond to both aluminum and the exact roofing substrate. It should also be rated for outdoor UV exposure, moisture, freeze-thaw cycles and expected service temperatures.
| Roof Surface |
Adhesive Guidance |
|
Asphalt Shingles
|
Use an exterior roofing adhesive or adhesive-sealant specifically approved for asphalt and aluminum. SureBond SB-190 Everseal is one example used for roof cable clip applications.
|
|
Metal Roof or Flashing
|
Use a high-strength roofing adhesive, adhesive-sealant or bonding product approved for aluminum and the specific metal surface.
|
|
EPDM / TPO / PVC Membrane
|
Use only a bonding adhesive or mastic approved by the membrane manufacturer for that exact roofing material.
|
|
Cedar or Wood
|
Use an exterior adhesive or adhesive-sealant approved for both wood and aluminum. Approved fasteners with compatible sealant may also be preferred.
|
|
Slate / Clay Tile / Concrete Tile
|
Consult the roofing manufacturer or qualified roofer for the correct mounting solution.
|
Before Bonding
Review adhesive technical data and roof requirements
Confirm the roof surface is clean, dry and suitable
Check minimum application temperature and curing requirements
Apply enough adhesive for proper clip contact
Allow full curing before installing or loading heating cable
Do not use hot glue, super glue or indoor-only adhesive products
Important: Adhesive, sealant, nails and screws are not included with the clips. Always use products approved for the specific roofing substrate.
Guide 4: Build a Complete Roof De-Icing System
A complete roof and gutter de-icing system requires compatible heating cable, mounting accessories and control components.
Step 2: Select Roof Clips
Choose RC-NF or RC-NG according to roof type and installation requirements.
Complete System Resources
Need Help Choosing Components?
If you are unsure which clip type, heating cable or pack size is suitable, send us your roof photos, roofing material details, cable dimensions and roof-edge measurements.
Contact YeloDeer support at
yelodeer@yelodeer.com
for product selection assistance.