YeloDeer Digital Thermostat, Plug-In Temperature Controlled Outlet, with Timer & 6.6ft Sensor Probe, Precise Temp Control for Reptile Greenhouse Pipe

SKU: EF03-HS
Regular price $17.99 USD Sale price $17.99 USD
Out of stock

Enjoy free shipping on orders over $30.

We ship orders within 48 hours for quick delivery.

1. Our website accepts Visa, MasterCard, and American Express. If you are using a card issued by another bank, please ensure it is enabled for international transactions.

2. During payment, you may be required to complete 3D Secure (3DS) verification. Please ensure that the cardholder completes the verification to avoid payment failure.

3. If your usual spending amounts are relatively low and you are making a larger purchase, your bank may flag the transaction as a potential risk. If your payment fails, please contact your bank to approve the transaction.

Questions & Answers

Have a Question?

Ask a Question
  • This device does not show a temperature below 34*. I am looking for something that will come on below 38* and off above 40*

    Dear Morgan,

    Thank you for your inquiry. Here’s the detailed response and setup guide to meet your requirements, based on our thermostat specifications and user manual:

    1. Temperature Range Clarification:

      • Display Range: -22–158°F (-30–70°C) — the controller fully supports displaying temperatures below 34°F, as its range covers down to -22°F.
      • Setting Range: 36–140°F (1–60°C) — the minimum adjustable heating activation temperature is 36°F, and it cannot be set lower than 36°F.
    2. On/Off Setting Adjustment (Meets Your Requirement):

      • Factory Default: The controller is preset to turn ON when the temperature falls below 37°F (3°C) and OFF when it rises above 47°F (8°C) (upper limit: +10°F / +5°C).
      • Your Requirement: Turn ON below 38°F and OFF above 40°F.
      • Solution: Adjust the upper limit to +3°F (2°C). With this setting:
        • The controller will turn ON when the temperature falls below 37°F (which meets your "ON below 38°F" need).
        • It will turn OFF when the temperature rises above 37°F + 3°F = 40°F (exactly matches your "OFF above 40°F" requirement).
    3. Step-by-Step Operation Guide (Per User Manual):

      • Step 1: Press & Hold O+ ↑ for 3s to Enter Advanced Settings
      • Step 2: Press ↑/↓ + O to Enter Setting 4.
      • Step 3: Press ▲ / ▼ to adjust the upper limit to +3°F (2°C).
      • Step 4: Press ◎ to confirm the setting.
    4. Additional Note:

      • The upper limit adjustment balances temperature accuracy and equipment start/stop frequency: A smaller upper limit value (like +3°F) ensures higher accuracy (matches your 40°F OFF target) but may result in slightly more frequent on/off cycles. Adjust according to your specific application needs.