{"product_id":"yelodeer-bulk-pg","title":"PG Bulk Self-Regulating Pipe Heat Tape Reel - Cut-to-Length Pipe Freeze Protection Cable | YeloDeer","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cdiv class=\"yd-product-section\"\u003e\n\u003cp\u003e\u003cstrong\u003ePG Bulk Self-Regulating Pipe Heat Tape Reel for Residential, Mobile Home \u0026amp; Light Commercial Pipe Freeze Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYeloDeer PG Bulk Self-Regulating Pipe Heat Tape is a professional cut-to-length heat trace cable reel designed for external water pipe freeze protection in residential, mobile home, farm, RV, and light commercial applications. It is ideal for home water pipes, crawl space plumbing, basement and garage pipes, manufactured home underbelly water lines, outdoor supply lines, and service jobs where fixed-length plug-in heat tape does not match the actual pipe layout.\u003c\/p\u003e\n\u003cp\u003ePG is a lightweight and economical pipe freeze protection cable for installers who need flexible job-site length control without moving into a heavier industrial heat trace system. It is smaller and more practical for ordinary pipe heat tape jobs, residential plumbing, mobile home service calls, farm water lines, and light commercial freeze protection work.\u003c\/p\u003e\n\u003cp\u003eUnlike pre-assembled heat tape, PG bulk reel cable can be cut on site. A plumber, electrician, contractor, mobile home service technician, or maintenance team can keep one reel and several connection kits in the truck, arrive at the job site, measure the actual pipe run, cut the cable to the required length, assemble the connection, seal the end, and install the system immediately.\u003c\/p\u003e\n\u003cdiv class=\"yd-hero-callout\"\u003e\n\u003cstrong\u003eCarry one reel. Cut what the job needs. Build the heat tape on site.\u003c\/strong\u003e \u003cspan\u003eA practical truck-stock pipe heat tape reel for winter service calls, custom pipe layouts, and multiple pipe sections.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003ch4\u003eWhy Installers Choose PG Bulk Reel\u003c\/h4\u003e\n\u003cdiv class=\"yd-scenario-grid\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eOn-Site Cut-to-Length Flexibility\u003c\/strong\u003e \u003cspan\u003eCut the cable to match the real pipe layout instead of ordering a fixed pre-assembled length and waiting for it to arrive.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eResidential \u0026amp; Mobile Home Ready\u003c\/strong\u003e \u003cspan\u003eUseful for home water pipes, crawlspaces, manufactured home water lines, skirted mobile home spaces, and exposed supply pipes.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eTruck-Stock Convenience\u003c\/strong\u003e \u003cspan\u003eKeep one PG reel, connection kits, and tee splice kits in a service vehicle for faster winter pipe freeze protection jobs.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eEconomical Light-Duty Solution\u003c\/strong\u003e \u003cspan\u003eDesigned for ordinary pipe heat tape applications where a smaller, cost-effective cable is more practical than a heavy-duty industrial heat trace system.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eSelf-Regulating Heat Output\u003c\/strong\u003e \u003cspan\u003eAutomatically adjusts heat output as pipe and ambient temperature changes. Suitable for straight, spiral, crossing, and properly overlapped installation.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eAdded Outer Jacket Protection\u003c\/strong\u003e \u003cspan\u003eCompared with braid-only freeze protection cables such as EasyHeat Freeze Free-style systems, PG includes a metal grounding shield plus an additional PE outer jacket.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eQuick Project Snapshot\u003c\/h4\u003e\n\u003cdiv class=\"yd-decision-strip\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eProduct Series\u003c\/strong\u003e \u003cspan\u003ePG self-regulating pipe heat tape reel \/ spool.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003ePrimary Use\u003c\/strong\u003e \u003cspan\u003eExternal water pipe freeze protection for residential, mobile home, farm, RV, and light commercial projects.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eStandard Output\u003c\/strong\u003e \u003cspan\u003e5W\/ft at 50°F \/ 10°C, 120V AC, PE outer jacket.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eCertification\u003c\/strong\u003e \u003cspan\u003ecCSAus certified for approved U.S. and Canadian pipe freeze protection applications.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eBest For\u003c\/h4\u003e\n\u003cdiv class=\"yd-category-grid\"\u003e\n\u003cdiv class=\"yd-category-card\"\u003e\n\u003cstrong\u003eHome \u0026amp; Residential Pipes\u003c\/strong\u003e\n\u003cdiv class=\"yd-mini-tags\"\u003e\n\u003cspan\u003eCrawl Space Pipes\u003c\/span\u003e \u003cspan\u003eBasement Pipes\u003c\/span\u003e \u003cspan\u003eGarage Pipes\u003c\/span\u003e \u003cspan\u003eOutdoor Water Lines\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"yd-category-card\"\u003e\n\u003cstrong\u003eMobile \u0026amp; Manufactured Homes\u003c\/strong\u003e\n\u003cdiv class=\"yd-mini-tags\"\u003e\n\u003cspan\u003eUnder-Home Water Lines\u003c\/span\u003e \u003cspan\u003eSkirted Crawlspaces\u003c\/span\u003e \u003cspan\u003eExposed Supply Pipes\u003c\/span\u003e \u003cspan\u003eService Calls\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"yd-category-card\"\u003e\n\u003cstrong\u003eFarm, RV \u0026amp; Property Use\u003c\/strong\u003e\n\u003cdiv class=\"yd-mini-tags\"\u003e\n\u003cspan\u003eFarm Water Lines\u003c\/span\u003e \u003cspan\u003eBarn Water Systems\u003c\/span\u003e \u003cspan\u003eRV Plumbing\u003c\/span\u003e \u003cspan\u003eGarden Supply Pipes\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"yd-category-card\"\u003e\n\u003cstrong\u003eProfessional Installers\u003c\/strong\u003e\n\u003cdiv class=\"yd-mini-tags\"\u003e\n\u003cspan\u003ePlumbers\u003c\/span\u003e \u003cspan\u003eElectricians\u003c\/span\u003e \u003cspan\u003eContractors\u003c\/span\u003e \u003cspan\u003eMaintenance Teams\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eImportant Before You Order\u003c\/h4\u003e\n\u003cdiv class=\"yd-alert-box\"\u003e\n\u003cp\u003e\u003cstrong\u003eThis is a bulk cut-to-length heat tape reel, not a ready-to-use plug-in cable.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEach cable section must be cut, connected, sealed, insulated, protected, and tested correctly before use. PG is best for professional installers or experienced DIY users who are comfortable with field assembly and electrical safety.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch4\u003eConnection Kit Reminder\u003c\/h4\u003e\n\u003cdiv class=\"yd-notice-box\"\u003e\n\u003cp\u003eEach 100 ft, 300 ft, or 500 ft PG reel kit includes \u003cstrong\u003eone standard connection kit\u003c\/strong\u003e. This is intentional because every project layout is different.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOne independent powered heating cable section needs one connection kit.\u003c\/strong\u003e If you cut a reel into multiple powered sections, add the required number of extra connection kits from this product page.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch4\u003eShips from U.S. and Canada Warehouses\u003c\/h4\u003e\n\u003cdiv class=\"yd-choice-grid\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eFast Winter Fulfillment\u003c\/strong\u003e \u003cspan\u003eStandard PG reels, connection kits, and tee splice kits mainly ship from U.S. and Canada warehouses.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eInstaller Inventory\u003c\/strong\u003e \u003cspan\u003eUseful for plumbers, electricians, mobile home service teams, and maintenance crews that need pipe heat tape on hand.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eProject Options\u003c\/strong\u003e \u003cspan\u003eSome special wattage, voltage, jacket, or project configurations may require additional lead time.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003ePG vs Pre-Assembled Heat Tape\u003c\/h4\u003e\n\u003cdiv class=\"yd-compare-grid\"\u003e\n\u003cdiv class=\"yd-compare-card\"\u003e\n\u003cstrong\u003eChoose PG Bulk Reel If\u003c\/strong\u003e \u003cspan\u003eYou need on-site cut-to-length flexibility, multiple pipe sections, branch layouts, contractor inventory, mobile home service work, or residential\/light commercial pipe freeze protection.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"yd-compare-card\"\u003e\n\u003cstrong\u003eChoose Pre-Assembled Cable If\u003c\/strong\u003e \u003cspan\u003eYou need a simple homeowner-ready cable with factory-installed plug and end seal for one fixed-length pipe section.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003ePG vs KDL\u003c\/h4\u003e\n\u003cdiv class=\"yd-compare-grid\"\u003e\n\u003cdiv class=\"yd-compare-card\"\u003e\n\u003cstrong\u003ePG: Lightweight \u0026amp; Economical\u003c\/strong\u003e \u003cspan\u003eBetter for ordinary pipe heat tape jobs, home water pipes, mobile homes, farms, RV plumbing, and light commercial freeze protection.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"yd-compare-card\"\u003e\n\u003cstrong\u003eKDL: Heavier-Duty Projects\u003c\/strong\u003e \u003cspan\u003eBetter for larger, longer, more demanding commercial, industrial, low-voltage, or hazardous-location project requirements.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eFor heavier-duty project heat trace, compare with \u003ca rel=\"noopener\" href=\"https:\/\/yelodeer.com\/collections\/external-pipe-heating-cables\/products\/yelodeer-cut-to-length-roof-deicing-cable\" target=\"_blank\"\u003e\u003cstrong\u003eYeloDeer KDL cut-to-length heating cable\u003c\/strong\u003e\u003c\/a\u003e. For internal pipe applications, see the \u003ca rel=\"noopener\" href=\"https:\/\/yelodeer.com\/collections\/in-pipe-heating-cable\" target=\"_blank\"\u003e\u003cstrong\u003eYeloDeer in-pipe heating cable collection\u003c\/strong\u003e\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch4\u003eNeed Help Planning a Project?\u003c\/h4\u003e\n\u003cp\u003eFor custom or complex installations, contact \u003ca href=\"mailto:yelodeer@yelodeer.com\"\u003e\u003cstrong\u003eyelodeer@yelodeer.com\u003c\/strong\u003e\u003c\/a\u003e with pipe diameter, pipe material, voltage, breaker size if known, total heating length, branch layout, photos, and whether you need straight trace, spiral wrap, tee connections, or multiple cable sections.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"YeloDeer PG bulk self-regulating pipe heat tape tee splice kit for branch layouts\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0701\/2836\/9905\/files\/T_e0b5666e-4d11-4e50-98da-7599f8bded80.jpg?v=1777541491\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"yd-video-wrap\"\u003e\u003ciframe title=\"YeloDeer PG Bulk Self-Regulating Pipe Heat Tape Installation Video\" src=\"https:\/\/www.youtube.com\/embed\/mzLr-E_3ais?si=aIAIfxILxIugVZE\"\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg alt=\"PG bulk self-regulating pipe heat tape for custom external pipe freeze protection\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0701\/2836\/9905\/files\/1_54d775b8-a834-4fcf-b687-81e5c9240f4e.jpg?v=1755687037\"\u003e \u003cimg alt=\"Cut-to-length pipe heat tape reel for residential and light commercial pipe layouts\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0701\/2836\/9905\/files\/2_89442ebb-2786-4c30-8654-27b7425ac9c7.jpg?v=1755687038\"\u003e \u003cimg alt=\"YeloDeer PG self-regulating pipe heat tape structure with outer jacket and grounding shield\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0701\/2836\/9905\/files\/9_74ca0c8e-b08a-4a0a-9e40-770fa5a71161.jpg?v=1755687038\"\u003e \u003cimg alt=\"PG bulk heat tape for PVC PEX copper steel and galvanized water pipes\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0701\/2836\/9905\/files\/3_c8c97048-2632-4856-a6c7-bcaf601fb8b8.jpg?v=1755687037\"\u003e \u003cimg alt=\"Pipe freeze protection cable for valves elbows fittings and branch pipe sections\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0701\/2836\/9905\/files\/10_4bf8b2fa-8c06-494c-8c84-0422a50cc2af.jpg?v=1755687038\"\u003e \u003cimg alt=\"PG bulk pipe heating cable installation details and connection accessories\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0701\/2836\/9905\/files\/11.jpg?v=1755687039\"\u003e \u003cimg alt=\"Custom pipe heating cable installation with insulation for winter freeze protection\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0701\/2836\/9905\/files\/4_ab38f6cb-4e2b-4cd7-98f3-74e361b23630.jpg?v=1755687038\"\u003e \u003cimg alt=\"Bulk self-regulating heat tape for outdoor water pipes farm lines and mobile home pipes\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0701\/2836\/9905\/files\/12_e987d763-423c-4580-a039-41c41407004f.jpg?v=1755687037\"\u003e \u003cimg alt=\"Connection kit and end seal accessories for PG bulk pipe heat cable\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0701\/2836\/9905\/files\/5_1d852d2e-f061-4bd7-b1e3-1d4f97e8038e.jpg?v=1755687037\"\u003e \u003cimg alt=\"Tee splice kit for three optional PG pipe heating cable connection layouts\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0701\/2836\/9905\/files\/13.jpg?v=1755687037\"\u003e \u003cimg alt=\"PG bulk pipe heat tape for contractor plumber electrician and maintenance installations\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0701\/2836\/9905\/files\/14.jpg?v=1755687037\"\u003e \u003cimg alt=\"External pipe heat tape for long exposed pipe runs and light commercial freeze protection\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0701\/2836\/9905\/files\/15.jpg?v=1755687037\"\u003e \u003cimg alt=\"YeloDeer PG bulk self-regulating pipe heat tape product details\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0701\/2836\/9905\/files\/16.jpg?v=1755687037\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv class=\"yd-product-section\"\u003e\n\u003ch4\u003eRecommended Applications\u003c\/h4\u003e\n\u003cp\u003eYeloDeer PG is designed for external pipe freeze protection where custom length, job-site flexibility, and reliable connection accessories are required.\u003c\/p\u003e\n\u003cdiv class=\"yd-category-grid\"\u003e\n\u003cdiv class=\"yd-category-card\"\u003e\n\u003cstrong\u003eHome \u0026amp; Residential Pipe Protection\u003c\/strong\u003e\n\u003cdiv class=\"yd-mini-tags\"\u003e\n\u003cspan\u003eCrawl Space Pipes\u003c\/span\u003e \u003cspan\u003eBasement Pipes\u003c\/span\u003e \u003cspan\u003eGarage Pipes\u003c\/span\u003e \u003cspan\u003eOutdoor Faucets\u003c\/span\u003e \u003cspan\u003eGarden Water Lines\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"yd-category-card\"\u003e\n\u003cstrong\u003eMobile \u0026amp; Manufactured Homes\u003c\/strong\u003e\n\u003cdiv class=\"yd-mini-tags\"\u003e\n\u003cspan\u003eUnder-Home Supply Lines\u003c\/span\u003e \u003cspan\u003eSkirted Crawlspaces\u003c\/span\u003e \u003cspan\u003eExposed Water Pipes\u003c\/span\u003e \u003cspan\u003eMobile Home Parks\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"yd-category-card\"\u003e\n\u003cstrong\u003eFarm, RV \u0026amp; Property Use\u003c\/strong\u003e\n\u003cdiv class=\"yd-mini-tags\"\u003e\n\u003cspan\u003eFarm Water Lines\u003c\/span\u003e \u003cspan\u003eBarn Water Systems\u003c\/span\u003e \u003cspan\u003eLivestock Supply Lines\u003c\/span\u003e \u003cspan\u003eRV Plumbing\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"yd-category-card\"\u003e\n\u003cstrong\u003eLight Commercial \u0026amp; Service Jobs\u003c\/strong\u003e\n\u003cdiv class=\"yd-mini-tags\"\u003e\n\u003cspan\u003eContractor Installations\u003c\/span\u003e \u003cspan\u003eMaintenance Work\u003c\/span\u003e \u003cspan\u003eWinter Service Calls\u003c\/span\u003e \u003cspan\u003eCustom Pipe Layouts\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eHome Water Pipe Freeze Protection\u003c\/h4\u003e\n\u003cp\u003ePG is suitable for ordinary home pipe heat tape applications where pipes are exposed to freezing conditions. Typical residential use includes crawl space pipes, basement pipes, garage pipes, outdoor water supply lines, outdoor faucets, and cold utility areas.\u003c\/p\u003e\n\u003cp\u003eBecause the cable is supplied as a reel, installers can cut the cable to match the pipe instead of forcing a fixed-length cable onto a layout that does not fit.\u003c\/p\u003e\n\u003ch4\u003eMobile Home \u0026amp; Manufactured Home Water Lines\u003c\/h4\u003e\n\u003cp\u003eMobile home and manufactured home water line freeze protection is an important application for PG, especially where water lines are exposed under the home, routed through skirted spaces, or located near crawlspace openings.\u003c\/p\u003e\n\u003cp\u003ePG bulk reel is useful for mobile home service work because the actual pipe route often varies from home to home. Installers can cut the cable on site, add the required number of connection kits, and adapt to main lines, branch lines, valves, and fittings.\u003c\/p\u003e\n\u003cp\u003eFor best performance under mobile homes, install suitable pipe insulation after the cable is secured and protect the insulation from moisture where needed.\u003c\/p\u003e\n\u003ch4\u003eCompatible Pipe Materials\u003c\/h4\u003e\n\u003cdiv class=\"yd-pill-grid\"\u003e\n\u003cspan\u003ePVC\u003c\/span\u003e \u003cspan\u003ePEX\u003c\/span\u003e \u003cspan\u003eCopper\u003c\/span\u003e \u003cspan\u003eSteel\u003c\/span\u003e \u003cspan\u003eGalvanized Pipe\u003c\/span\u003e \u003cspan\u003eSuitable Plastic Pipes\u003c\/span\u003e \u003cspan\u003eSuitable Metal Pipes\u003c\/span\u003e \u003cspan\u003eWater-Filled or Empty Rigid Pipes\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe pipe must be clean, dry, undamaged, and safe to heat. Do not install on cracked, leaking, or unsafe pipe.\u003c\/p\u003e\n\u003ch4\u003eInstallation Methods\u003c\/h4\u003e\n\u003cdiv class=\"yd-rule-grid\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eStraight Tracing\u003c\/strong\u003e \u003cspan\u003eRun the cable along the pipe for standard pipe freeze protection layouts.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eSpiral Wrapping\u003c\/strong\u003e \u003cspan\u003eWrap the cable around the pipe when additional coverage is needed for colder or more exposed sections.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eCrossing \u0026amp; Overlapping\u003c\/strong\u003e \u003cspan\u003eBecause PG is self-regulating, properly installed crossing and overlapping are allowed around valves, fittings, and irregular sections.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eSecondary Field Uses\u003c\/h4\u003e\n\u003cdiv class=\"yd-notice-box\"\u003e\n\u003cp\u003eSome users also apply self-regulating heat cable for winter protection around animal water systems, garden lines, RV plumbing, or plant\/palm protection. These should be treated as secondary field uses.\u003c\/p\u003e\n\u003cp\u003eThe main certified application is pipe freeze protection. The installer must evaluate safety, moisture protection, electrical protection, and code compliance for any non-standard use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch4\u003eWhen Not to Use This Product\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eGas, fuel, or chemical lines unless specifically approved\u003c\/li\u003e\n\u003cli\u003eLong-term submersion with standard PE jacket configuration\u003c\/li\u003e\n\u003cli\u003eSteam lines or pipes above the product temperature limits\u003c\/li\u003e\n\u003cli\u003eDamaged, leaking, or unsafe pipes\u003c\/li\u003e\n\u003cli\u003eInstallations where electrical connections cannot be protected\u003c\/li\u003e\n\u003cli\u003eUsers who need a simple ready-to-use plug-in product\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor internal pipe heating, use the appropriate \u003ca rel=\"noopener\" href=\"https:\/\/yelodeer.com\/collections\/in-pipe-heating-cable\" target=\"_blank\"\u003e\u003cstrong\u003eYeloDeer in-pipe heating cable configuration\u003c\/strong\u003e\u003c\/a\u003e. CT fluoropolymer-jacket configurations may be used for internal pipe applications only when paired with the proper in-pipe connection kit and installed according to the correct product instructions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv class=\"yd-product-section\"\u003e\n\u003ch4\u003eStandard Product Specifications\u003c\/h4\u003e\n\u003ctable class=\"yd-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003ePG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eBulk self-regulating pipe heat tape reel \/ spool\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Application\u003c\/td\u003e\n\u003ctd\u003eExternal pipe freeze protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Use\u003c\/td\u003e\n\u003ctd\u003eResidential, mobile home, manufactured home, farm, RV, and light commercial pipe freeze protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Voltage\u003c\/td\u003e\n\u003ctd\u003e120V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Output\u003c\/td\u003e\n\u003ctd\u003e5W\/ft at 50°F \/ 10°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Technology\u003c\/td\u003e\n\u003ctd\u003eSelf-regulating PTC heating core\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Jacket\u003c\/td\u003e\n\u003ctd\u003ePE outer jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrounding Layer\u003c\/td\u003e\n\u003ctd\u003eMetal grounding shield \/ braid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Project Configurations\u003c\/td\u003e\n\u003ctd\u003e3W\/ft, 5W\/ft, 8W\/ft; 120V or 240V; PE or ETFE jacket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Pipes\u003c\/td\u003e\n\u003ctd\u003eSuitable plastic and metal water pipes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Methods\u003c\/td\u003e\n\u003ctd\u003eStraight, spiral, crossing, and overlapping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius\u003c\/td\u003e\n\u003ctd\u003e1 in \/ 25 mm at 68°F \/ 20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Length\u003c\/td\u003e\n\u003ctd\u003e3 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Size\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.3 × 0.2 in \/ 8 × 5.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-In Thermostat\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-In GFCI\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlug\u003c\/td\u003e\n\u003ctd\u003eGrounded indicator plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003ecCSAus certified for approved U.S. and Canadian pipe freeze protection applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eReel \/ Spool and Accessory Options\u003c\/h4\u003e\n\u003cdiv class=\"yd-pill-grid\"\u003e\n\u003cspan\u003e100 ft PG Reel Kit\u003c\/span\u003e \u003cspan\u003e300 ft PG Reel Kit\u003c\/span\u003e \u003cspan\u003e500 ft PG Reel Kit\u003c\/span\u003e \u003cspan\u003eConnection Kit, 1PC\u003c\/span\u003e \u003cspan\u003eConnection Kit, 2PC\u003c\/span\u003e \u003cspan\u003eConnection Kit, 4PC\u003c\/span\u003e \u003cspan\u003eIP68 Tee Splice Kit\u003c\/span\u003e \u003cspan\u003eProject Options Available\u003c\/span\u003e\n\u003c\/div\u003e\n\u003ch4\u003eMaximum Circuit Length\u003c\/h4\u003e\n\u003cdiv class=\"yd-alert-box\"\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum circuit length is not one fixed number for every installation.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt depends on cable output, voltage, circuit breaker size, minimum start-up temperature, total connected cable length, and whether the system uses branch or tee splice layouts.\u003c\/p\u003e\n\u003cp\u003eAlways follow the \u003cstrong\u003eMaximum Circuit Length vs. Breaker Size\u003c\/strong\u003e table in the PG manual when planning a circuit. For tee splice layouts, calculate the combined length of all cable sections connected to the same power connection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"yd-check-grid\"\u003e\n\u003cspan\u003eCable output: 3W\/ft, 5W\/ft, or 8W\/ft\u003c\/span\u003e \u003cspan\u003eVoltage: 120V or 240V\u003c\/span\u003e \u003cspan\u003eCircuit breaker size\u003c\/span\u003e \u003cspan\u003eMinimum start-up temperature\u003c\/span\u003e \u003cspan\u003eTotal connected cable length\u003c\/span\u003e \u003cspan\u003eBranch or tee splice layout\u003c\/span\u003e\n\u003c\/div\u003e\n\u003ch4\u003eHow Many Connection Kits Do You Need?\u003c\/h4\u003e\n\u003cdiv class=\"yd-notice-box\"\u003e\n\u003cp\u003e\u003cstrong\u003eOne independent powered heating cable section = one connection kit.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYeloDeer includes one standard connection kit with each PG reel. Additional kits are available because every job-site layout is different.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"yd-rule-grid\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eOne Section\u003c\/strong\u003e \u003cspan\u003eOne 80 ft home pipe or mobile home water line usually needs one connection kit.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eMultiple Sections\u003c\/strong\u003e \u003cspan\u003eTwo separate pipe runs usually need two connection kits. Three separate sections usually need three connection kits.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eBulk Reel Planning\u003c\/strong\u003e \u003cspan\u003eA 300 ft or 500 ft reel may be cut into multiple sections. Add connection kits based on the number of powered sections.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003ePE Jacket vs ETFE Jacket\u003c\/h4\u003e\n\u003cdiv class=\"yd-compare-grid\"\u003e\n\u003cdiv class=\"yd-compare-card\"\u003e\n\u003cstrong\u003ePE Jacket\u003c\/strong\u003e \u003cspan\u003eStandard economical jacket for common external pipe freeze protection projects. Adds a protective layer over the grounding shield.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"yd-compare-card\"\u003e\n\u003cstrong\u003eETFE Jacket\u003c\/strong\u003e \u003cspan\u003eOptional fluoropolymer jacket for project requirements that need higher chemical resistance, higher durability, or internal pipe configurations with the proper connection kit.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003ePG vs KDL Selection\u003c\/h4\u003e\n\u003ctable class=\"yd-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eChoose PG\u003c\/td\u003e\n\u003ctd\u003eFor lightweight, economical residential and light commercial pipe freeze protection, including home pipes, mobile homes, farms, RV plumbing, crawlspaces, and ordinary pipe heat tape jobs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChoose KDL\u003c\/td\u003e\n\u003ctd\u003eFor heavier-duty residential, commercial, industrial, low-voltage, or hazardous-location project requirements where a stronger heat trace system and project-specific accessories are needed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCompare with \u003ca rel=\"noopener\" href=\"https:\/\/yelodeer.com\/collections\/external-pipe-heating-cables\/products\/yelodeer-cut-to-length-roof-deicing-cable\" target=\"_blank\"\u003e\u003cstrong\u003eYeloDeer KDL cut-to-length heating cable\u003c\/strong\u003e\u003c\/a\u003e if your project requires a heavier-duty heat trace system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eInstallation\u003c\/h3\u003e\n\u003cdiv class=\"yd-product-section\"\u003e\n\u003ch4\u003eInstallation Overview\u003c\/h4\u003e\n\u003cp\u003ePG is a field-assembled product. It is intended for users with suitable installation ability or professional support.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eInspect the pipe layout.\u003c\/li\u003e\n\u003cli\u003eMeasure each heating section.\u003c\/li\u003e\n\u003cli\u003eDecide straight trace, spiral wrap, overlap, or tee layout.\u003c\/li\u003e\n\u003cli\u003eCheck the maximum circuit length table.\u003c\/li\u003e\n\u003cli\u003eCut the cable to the required length.\u003c\/li\u003e\n\u003cli\u003eAssemble the power connection with the PG connection kit.\u003c\/li\u003e\n\u003cli\u003eInstall the end seal on the cut end.\u003c\/li\u003e\n\u003cli\u003eSecure the cable along the outside of the pipe.\u003c\/li\u003e\n\u003cli\u003eUse the Tee Splice Kit if the layout requires a branch connection.\u003c\/li\u003e\n\u003cli\u003eAdd suitable pipe insulation.\u003c\/li\u003e\n\u003cli\u003eConnect to a properly grounded GFCI-protected outlet or protected circuit.\u003c\/li\u003e\n\u003cli\u003eTest the indicator light and verify heating before winter operation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch4\u003eConnection Kit\u003c\/h4\u003e\n\u003cp\u003eThe PG connection kit is used to create one powered heating cable section. It provides the components needed for one power connection and one end seal.\u003c\/p\u003e\n\u003cdiv class=\"yd-choice-grid\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eOne Cable Section\u003c\/strong\u003e \u003cspan\u003eEach independent powered heating cable section needs one connection kit.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eOne Kit Included\u003c\/strong\u003e \u003cspan\u003eEach PG reel kit includes one standard connection kit for one basic section.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eExtra Kits Available\u003c\/strong\u003e \u003cspan\u003eIf the reel is cut into multiple powered sections, add the required number of extra connection kits from this page.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eWhy YeloDeer Does Not Include Many Connection Kits by Default\u003c\/h4\u003e\n\u003cdiv class=\"yd-notice-box\"\u003e\n\u003cp\u003eEvery installer uses bulk reel cable differently. Some users may install one 100 ft section. Others may cut a 300 ft or 500 ft reel into several sections for home pipes, mobile homes, farms, RV plumbing systems, or crawlspaces.\u003c\/p\u003e\n\u003cp\u003eIncluding too many kits by default would increase cost for users who do not need them. YeloDeer includes one kit with each reel, and customers can add the number of extra kits required by the actual job layout.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch4\u003eTee Splice Kit: 3 Optional Connection Layouts\u003c\/h4\u003e\n\u003cp\u003eThe PG Tee Splice Kit is designed for branch pipe layouts and multi-direction pipe heating. It is especially useful for crawlspace plumbing, manufactured home underbelly pipes, farm water systems, and contractor jobs where the pipe route is not a single straight line.\u003c\/p\u003e\n\u003cdiv class=\"yd-choice-grid\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e1. Main Line with Side Branch\u003c\/strong\u003e \u003cspan\u003eUse when a heated pipe run continues in one direction and a branch line needs freeze protection from the same connection point.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e2. Center-Feed Two-Direction Layout\u003c\/strong\u003e \u003cspan\u003eUse when the power point is near the middle of the pipe route and heating cable needs to run in two directions from that point.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e3. T-Intersection \/ Vertical Branch\u003c\/strong\u003e \u003cspan\u003eUse when the pipe route has a T-shaped branch, such as one main line with a perpendicular branch line.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"yd-alert-box\"\u003e\n\u003cp\u003eFor all tee splice layouts, calculate the total connected cable length and verify it against the maximum circuit length table in the PG manual.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch4\u003eResidential \u0026amp; Mobile Home Installation Notes\u003c\/h4\u003e\n\u003cp\u003eBefore cutting the reel, inspect the full pipe layout and check the number of independent sections required.\u003c\/p\u003e\n\u003cdiv class=\"yd-check-grid\"\u003e\n\u003cspan\u003eMain supply line length\u003c\/span\u003e \u003cspan\u003eBranch line locations\u003c\/span\u003e \u003cspan\u003eValves and fittings\u003c\/span\u003e \u003cspan\u003eCrawlspace or under-home exposure\u003c\/span\u003e \u003cspan\u003eDistance to power source\u003c\/span\u003e \u003cspan\u003eNumber of connection kits required\u003c\/span\u003e \u003cspan\u003eTee splice requirements\u003c\/span\u003e \u003cspan\u003eInsulation and waterproof covering\u003c\/span\u003e\n\u003c\/div\u003e\n\u003ch4\u003eElectrical Protection\u003c\/h4\u003e\n\u003cdiv class=\"yd-alert-box\"\u003e\n\u003cp\u003eThis product does not include built-in GFCI. Each heating cable branch circuit must be protected by an approved equipment ground-fault protection device \/ GFCI according to applicable electrical codes.\u003c\/p\u003e\n\u003cp\u003eUse a properly grounded outlet or branch circuit. Do not overload the outlet. If an extension cord is required, use only a properly sized grounded cord suitable for outdoor use and approved by an electrician.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch4\u003eInsulation Requirement\u003c\/h4\u003e\n\u003cdiv class=\"yd-scenario-grid\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eReduce Heat Loss\u003c\/strong\u003e \u003cspan\u003ePipe insulation helps keep heat around the protected pipe section.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eImprove Freeze Protection\u003c\/strong\u003e \u003cspan\u003eEspecially important for outdoor, windy, crawlspace, farm, RV, or under-home pipe runs.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eProtect the System\u003c\/strong\u003e \u003cspan\u003eIn wet or exposed areas, use waterproof covering or vapor barrier protection over the insulation.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eUse fiberglass or other suitable non-flammable pipe insulation. For severe cold conditions, use thicker insulation where appropriate.\u003c\/p\u003e\n\u003ch4\u003eSafety Notes\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFollow the maximum circuit length table in the PG manual.\u003c\/li\u003e\n\u003cli\u003eDo not exceed the allowed circuit length for the selected cable, voltage, breaker size, and start-up temperature.\u003c\/li\u003e\n\u003cli\u003eDo not install on damaged pipes.\u003c\/li\u003e\n\u003cli\u003eDo not energize the cable before the end seal is properly installed.\u003c\/li\u003e\n\u003cli\u003eDo not leave conductors, braid, or internal layers exposed.\u003c\/li\u003e\n\u003cli\u003eDo not install too close to external heat sources.\u003c\/li\u003e\n\u003cli\u003eDo not install on steam lines or pipes above the rated temperature limits.\u003c\/li\u003e\n\u003cli\u003eDo not twist, crush, sharply bend, staple, nail, or damage the cable.\u003c\/li\u003e\n\u003cli\u003eDo not substitute unapproved parts.\u003c\/li\u003e\n\u003cli\u003eDo not use ordinary vinyl electrical tape as a substitute for required connection components.\u003c\/li\u003e\n\u003cli\u003eDe-energize all power circuits before installation or service.\u003c\/li\u003e\n\u003cli\u003eIf the indicator light does not turn on, unplug the cable and recheck the connection before continuing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cdiv class=\"yd-product-section yd-faq-section\"\u003e\n\u003ch4\u003eProduct Basics\u003c\/h4\u003e\n\u003cdetails\u003e\n\u003csummary\u003eIs this product called PG or PGB?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe product series is PG. PG stands for Pipe Guard. It is a self-regulating pipe heating cable designed mainly for pipe freeze protection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eIs this a ready-to-use plug-in heat tape?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eNo. This is a bulk cut-to-length heat tape reel. It must be cut, connected, sealed, insulated, and tested before use. If you want a simple plug-in product, choose a pre-assembled pipe heat cable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat is PG best used for?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003ePG is best for residential, mobile home, farm, RV, and light commercial pipe freeze protection where installers need to cut cable to the actual pipe layout.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eIs this product only for mobile homes?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eNo. Mobile homes are an important application, but PG is also suitable for ordinary home water pipes, crawlspaces, basements, garages, outdoor supply lines, farms, RV plumbing, and light commercial pipe freeze protection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhy is PG useful for plumbers and electricians?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003ePG lets installers keep a reel in the truck and cut the cable on site. This avoids ordering the wrong pre-assembled length and helps installers respond faster to home pipe, mobile home, crawlspace, farm, RV, and emergency freeze protection jobs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003ch4\u003eCutting, Reel, and Connection Kits\u003c\/h4\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhy does each reel include only one connection kit?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eBecause every installation is different. One customer may use one long cable section, while another may cut the reel into several sections. YeloDeer includes one standard connection kit with each reel, and customers can buy additional kits based on the actual number of powered sections needed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow many connection kits do I need?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eEach independent powered heating section needs one connection kit. If you cut the reel into three separate powered sections, you need three connection kits.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan I use a 300 ft or 500 ft reel as one continuous powered run?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eDo not assume the entire reel can be used as one circuit. Maximum circuit length depends on cable wattage, voltage, breaker size, minimum start-up temperature, and layout. Always follow the maximum circuit length table in the PG manual.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan plumbers or electricians cut this cable into multiple sections?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eYes. That is one of the main reasons to use a bulk reel. A contractor can cut the reel into multiple custom sections for homes, mobile homes, crawlspaces, farms, RV plumbing, or property maintenance jobs, as long as each section is connected, sealed, insulated, and protected correctly.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan one power connection feed multiple cables?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eOne standard power connection is for one cable section unless the installation uses the correct approved splice or tee branch kit. Do not insert multiple independent cable ends into one standard power connection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003ch4\u003eTee Splice Kit\u003c\/h4\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat is the Tee Splice Kit used for?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe Tee Splice Kit is used for branch layouts, T-intersections, and multi-direction pipe heating. It is useful when the pipe system is not a simple straight run.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat are the three optional tee connection layouts?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe Tee Splice Kit can support a main line with a side branch, a center-feed layout that sends cable in two directions, or a T-intersection \/ vertical branch layout. Choose the layout based on the pipe route and power location.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eIs the Tee Splice Kit useful for mobile homes and crawlspaces?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eYes. Mobile home, manufactured home, and crawlspace plumbing often includes branch lines, utility points, valves, and non-straight pipe routing. A tee splice kit can help installers adapt the heat tape layout to the actual plumbing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003ch4\u003eProfessional Installation Questions\u003c\/h4\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat does 5W\/ft at 50°F \/ 10°C mean?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eIt means the cable’s nominal heating output is rated at 5 watts per foot when measured at 50°F \/ 10°C, which is a common reference temperature for self-regulating heating cable ratings.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat affects maximum circuit length?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eMaximum circuit length depends on cable wattage, voltage, breaker size, minimum start-up temperature, and layout. Use the manual’s maximum circuit length table before final installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat is the minimum bend radius?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe minimum bend radius is 1 in \/ 25 mm at 68°F \/ 20°C. Do not sharply bend, crush, or kink the cable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan this cable overlap itself?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eYes. Because it is self-regulating, the cable can cross or overlap itself when installed properly. This is useful around valves, elbows, tees, and irregular pipe sections.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan it be installed on plastic pipe?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eYes. It can be used on suitable plastic pipes such as PVC and PEX, as well as metal pipes such as copper, steel, and galvanized pipe. Use insulation after installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eDoes it need pipe insulation?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eYes. Pipe insulation is strongly recommended. Insulation improves freeze protection, reduces heat loss, and is especially important for outdoor pipes, crawlspaces, farms, RV plumbing, and exposed under-home water lines.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan it be installed on empty pipes?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eYes. It can be used on empty and water-filled rigid plastic or metal pipes when installed correctly and within the product limits.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003ch4\u003ePG, KDL, and In-Pipe Options\u003c\/h4\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhen should I choose PG instead of KDL?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eChoose PG for lightweight, economical residential and light commercial pipe freeze protection, especially home pipes, mobile homes, crawlspaces, farms, RV plumbing, and ordinary pipe heat tape jobs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhen should I choose KDL instead of PG?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eChoose \u003ca rel=\"noopener\" href=\"https:\/\/yelodeer.com\/collections\/external-pipe-heating-cables\/products\/yelodeer-cut-to-length-roof-deicing-cable\" target=\"_blank\"\u003e\u003cstrong\u003eKDL\u003c\/strong\u003e\u003c\/a\u003e for heavier-duty residential, commercial, industrial, low-voltage, or hazardous-location project requirements where a stronger heat trace system and project-specific accessories are needed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan PG be used inside a pipe?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe standard external pipe version is for outside-the-pipe installation. For internal pipe applications, use CT fluoropolymer jacket configurations with the proper in-pipe connection kit. Check the \u003ca rel=\"noopener\" href=\"https:\/\/yelodeer.com\/collections\/in-pipe-heating-cable\" target=\"_blank\"\u003e\u003cstrong\u003eYeloDeer in-pipe heating cable collection\u003c\/strong\u003e\u003c\/a\u003e for the correct product.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003ch4\u003eCertification \u0026amp; Safety\u003c\/h4\u003e\n\u003cdetails\u003e\n\u003csummary\u003eIs this cable cCSAus certified?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eYes. YeloDeer PG series self-regulating heating cable is certified by CSA Group with the cCSAus mark for approved U.S. and Canadian pipe freeze protection applications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhich standards apply?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe certification project is based on applicable North American pipe heating cable standards including CSA C22.2 No.130 and IEEE 515 series requirements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eDoes the plug include GFCI?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eNo. The plug is a grounded indicator plug, not a GFCI plug. The heating cable circuit must be protected by an approved GFCI or equipment ground-fault protection device.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eDoes this cable have a built-in thermostat?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eNo. The cable is self-regulating, but it does not include a built-in thermostat. For better energy control, use a compatible thermostat or controller.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan I use this cable for roof and gutter de-icing?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003ePG is positioned mainly for pipe freeze protection. For roof, gutter, and heavier-duty project applications, compare with \u003ca rel=\"noopener\" href=\"https:\/\/yelodeer.com\/collections\/external-pipe-heating-cables\/products\/yelodeer-cut-to-length-roof-deicing-cable\" target=\"_blank\"\u003e\u003cstrong\u003eYeloDeer KDL cut-to-length heating cable\u003c\/strong\u003e\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003ch4\u003eStock, Shipping \u0026amp; Selection Help\u003c\/h4\u003e\n\u003cdetails\u003e\n\u003csummary\u003eIs this product in stock?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eYes. Standard PG reels, connection kits, and tee splice kits are typically in stock and mainly ship from U.S. and Canada warehouses for faster fulfillment. Some special project configurations may require additional lead time.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhy is warehouse stock important for installers?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003ePipe freeze protection is often seasonal and urgent. In-stock reels and accessories help plumbers, electricians, mobile home technicians, and maintenance teams respond faster during cold weather.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat should I send before asking for help?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eSend pipe material, pipe diameter, total pipe length, number of separate pipe sections, lowest expected temperature, voltage, breaker size if known, whether the pipe is under a home, outdoors, on a farm, in an RV, or in a crawlspace, whether the layout has branches, and photos of the pipe and power location.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhen should I choose plug-in pipe heat cable instead?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eChoose plug-in heat cable if you want a simple ready-to-use product, do not want to assemble a power connection, only need one fixed-length pipe section, or are not comfortable with electrical installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e","brand":"YeloDeer","offers":[{"title":"100ft-Kit","offer_id":46815356059889,"sku":"100ft-Kit","price":99.99,"currency_code":"USD","in_stock":true},{"title":"300ft-Kit","offer_id":46815356092657,"sku":"300ft-Kit","price":284.99,"currency_code":"USD","in_stock":false},{"title":"500ft-Kit","offer_id":46815356125425,"sku":"500ft-Kit","price":379.99,"currency_code":"USD","in_stock":true},{"title":"IP68 Tee Splice Kit","offer_id":48114294423793,"sku":"PGB-Kit-T","price":28.99,"currency_code":"USD","in_stock":true},{"title":"Connection Kit (1PC)","offer_id":46815356158193,"sku":"Connection Kit (1PC)","price":16.99,"currency_code":"USD","in_stock":true},{"title":"Connection Kit (2PC)","offer_id":46815356190961,"sku":"Connection Kit (2PC)","price":28.99,"currency_code":"USD","in_stock":true},{"title":"Connection Kit (4PC)","offer_id":46815356223729,"sku":"Connection Kit (4PC)","price":51.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0701\/2836\/9905\/files\/6391ace427ade714b70fb966024ae804_09170e0e-051d-4d45-b892-e6316ad7915c.jpg?v=1766975809","url":"https:\/\/yelodeer.com\/products\/yelodeer-bulk-pg","provider":"YeloDeer","version":"1.0","type":"link"}