{"product_id":"self-regulating-pipe-heat-cable-digital-thermostat","title":"Plug-In Self-Regulating Pipe Heat Cable with Digital Thermostat","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cdiv class=\"yd-product-section\"\u003e\n\u003cp\u003e\u003cstrong\u003eSelf-Regulating Pipe Heat Cable with Integrated Digital Temperature Control\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis thermostatic model upgrades YeloDeer's yellow self-regulating pipe heat cable with an integrated digital thermostat and remote pipe sensor. It combines temperature-responsive self-regulating heat with automatic thermostat control for external pipe freeze protection.\u003c\/p\u003e\n\n\u003cdiv class=\"yd-decision-strip\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e120V Plug-In\u003c\/strong\u003e\n\u003cspan\u003ePreassembled for use with a properly grounded and ground-fault-protected 120V outlet.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e6W\/ft at 50°F\u003c\/strong\u003e\n\u003cspan\u003eSelf-regulating heating cable adjusts heat output as surrounding conditions change.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e36–140°F Control\u003c\/strong\u003e\n\u003cspan\u003eAdjust the thermostat setpoint from 36°F to 140°F \/ 1°C to 60°C.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e6.6 ft Pipe Sensor\u003c\/strong\u003e\n\u003cspan\u003ePlace the remote sensor at the coldest protected pipe location for targeted temperature control.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eWhat Is Included?\u003c\/h4\u003e\n\u003cdiv class=\"yd-do-dont-grid\"\u003e\n\u003cdiv class=\"yd-do-card\"\u003e\n\u003cstrong\u003eIncluded with the Cable\u003c\/strong\u003e\n\u003cspan\u003e1 thermostatic heating cable, 1 instruction manual, 1 end seal, 1 self-adhesive tape, and 1 aluminum foil tape.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"yd-dont-card\"\u003e\n\u003cstrong\u003ePlan for Pipe Insulation\u003c\/strong\u003e\n\u003cspan\u003ePipe insulation is not included. Suitable non-flammable pipe insulation and a waterproof outer wrap are required for proper installation. Additional securing materials may also be needed depending on the layout.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eUpgraded Thermostat Version or Yellow Basic Version?\u003c\/h4\u003e\n\u003cdiv class=\"yd-compare-grid\"\u003e\n\u003cdiv class=\"yd-compare-card\"\u003e\n\u003cstrong\u003eThis Thermostatic Upgrade\u003c\/strong\u003e\n\u003cp\u003eIncludes an integrated digital thermostat and 6.6 ft remote sensor. Provides automatic temperature-based heating control, an adjustable setpoint, temperature display, timer, sensor calibration, and forced heating mode.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"yd-compare-card\"\u003e\n\u003cstrong\u003eYellow Basic Version\u003c\/strong\u003e\n\u003cp\u003eNo built-in thermostat. Heating begins whenever the cable receives power, while the self-regulating core adjusts heat output along the cable. Add a separate controller if automatic power control is needed.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/yelodeer.com\/collections\/external-pipe-heating-cables\/products\/pipe-heat-cable-yellow\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eCompare the Yellow Version Without Thermostat →\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"yd-notice-box\"\u003e\n\u003cp\u003e\u003cstrong\u003eSelf-regulating and thermostatic control do different jobs.\u003c\/strong\u003e The self-regulating cable changes heat output locally as pipe temperature changes. The thermostat monitors the remote sensor and can switch heating operation on or off according to the selected temperature setting.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eDefault Freeze-Protection Setting\u003c\/h4\u003e\n\u003cdiv class=\"yd-check-grid\"\u003e\n\u003cspan\u003eFactory setpoint: 37°F \/ 3°C\u003c\/span\u003e\n\u003cspan\u003eDefault upper limit: +10°F \/ +5°C\u003c\/span\u003e\n\u003cspan\u003eHeating starts below the set temperature\u003c\/span\u003e\n\u003cspan\u003eDefault heating stops above approximately 47°F \/ 8°C\u003c\/span\u003e\n\u003c\/div\u003e\n\n\u003cp\u003eFor most basic pipe freeze-protection applications, the factory setting can be used without adjustment. Change the temperature settings only when the installation requires a different control range.\u003c\/p\u003e\n\n\u003ch4\u003eBefore Ordering\u003c\/h4\u003e\n\u003cdiv class=\"yd-check-grid\"\u003e\n\u003cspan\u003e120V AC power is available\u003c\/span\u003e\n\u003cspan\u003ePipe diameter is 1\/2 in to 2 in\u003c\/span\u003e\n\u003cspan\u003eInstallation is on the outside of the pipe\u003c\/span\u003e\n\u003cspan\u003ePipe is rigid plastic or metal\u003c\/span\u003e\n\u003cspan\u003eA cold pipe location is available for the sensor\u003c\/span\u003e\n\u003cspan\u003eSuitable pipe insulation can cover the cable and sensor\u003c\/span\u003e\n\u003cspan\u003eOutlet has required ground-fault protection\u003c\/span\u003e\n\u003cspan\u003ePipe surface will not exceed 140°F \/ 60°C\u003c\/span\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"yd-alert-box\"\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e The temperature sensor must contact the pipe itself, not the heating cable. Direct sensor-to-cable contact can produce an inaccurate temperature reading and cause the system to cycle incorrectly.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv class=\"yd-product-section\"\u003e\n\u003ch4\u003eRecommended Applications\u003c\/h4\u003e\n\u003cdiv class=\"yd-category-grid\"\u003e\n\u003cdiv class=\"yd-category-card\"\u003e\n\u003cstrong\u003eResidential Pipe Protection\u003c\/strong\u003e\n\u003cdiv class=\"yd-mini-tags\"\u003e\n\u003cspan\u003eOutdoor Water Pipes\u003c\/span\u003e\n\u003cspan\u003eCrawl Spaces\u003c\/span\u003e\n\u003cspan\u003eBasements\u003c\/span\u003e\n\u003cspan\u003eGarages\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"yd-category-card\"\u003e\n\u003cstrong\u003eFarm \u0026amp; Utility Pipes\u003c\/strong\u003e\n\u003cdiv class=\"yd-mini-tags\"\u003e\n\u003cspan\u003eFarm Water Lines\u003c\/span\u003e\n\u003cspan\u003eBarn Plumbing\u003c\/span\u003e\n\u003cspan\u003eExposed Supply Pipes\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"yd-category-card\"\u003e\n\u003cstrong\u003eSeasonal Properties\u003c\/strong\u003e\n\u003cdiv class=\"yd-mini-tags\"\u003e\n\u003cspan\u003eCabins\u003c\/span\u003e\n\u003cspan\u003eSeasonal Buildings\u003c\/span\u003e\n\u003cspan\u003eCold Utility Areas\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"yd-category-card\"\u003e\n\u003cstrong\u003eRigid Pipe Systems\u003c\/strong\u003e\n\u003cdiv class=\"yd-mini-tags\"\u003e\n\u003cspan\u003ePlastic Pipe\u003c\/span\u003e\n\u003cspan\u003eMetal Pipe\u003c\/span\u003e\n\u003cspan\u003eEmpty Pipes\u003c\/span\u003e\n\u003cspan\u003eWater-Filled Pipes\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003ePipe Compatibility\u003c\/h4\u003e\n\u003ctable class=\"yd-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePipe Diameter\u003c\/td\u003e\n\u003ctd\u003e1\/2 in to 2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePipe Type\u003c\/td\u003e\n\u003ctd\u003eEmpty or water-filled rigid plastic and metal pipes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Location\u003c\/td\u003e\n\u003ctd\u003eOutside the pipe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Layout\u003c\/td\u003e\n\u003ctd\u003eStraight, spiral, or properly doubled-back installation according to the instruction manual and required cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eDo Not Use This Product For\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInstallation inside a water pipe, drain, sewer line, or other piping system\u003c\/li\u003e\n\u003cli\u003eRoof or gutter de-icing\u003c\/li\u003e\n\u003cli\u003eLong-term submersion of the thermostat, plug, or electrical connections\u003c\/li\u003e\n\u003cli\u003eDamaged, leaking, or structurally unsafe pipe\u003c\/li\u003e\n\u003cli\u003ePipes exposed to temperatures above 140°F \/ 60°C, including steam-line applications\u003c\/li\u003e\n\u003cli\u003eLocations where the controller or electrical connection cannot be kept dry and properly protected\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv class=\"yd-notice-box\"\u003e\n\u003cp\u003eChoose cable length based on pipe material, pipe diameter, protected pipe length, and the lowest expected ambient temperature. Use the cable-sizing table in the instruction manual rather than selecting length from pipe length alone in severe cold conditions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv class=\"yd-product-section\"\u003e\n\u003ch4\u003eProduct Specifications\u003c\/h4\u003e\n\u003ctable class=\"yd-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSelf-regulating external pipe heat cable with integrated digital thermostat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e120V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Output\u003c\/td\u003e\n\u003ctd\u003e6W\/ft at 50°F \/ 10°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePipe Diameter\u003c\/td\u003e\n\u003ctd\u003e1\/2 in to 2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Pipe Type\u003c\/td\u003e\n\u003ctd\u003eEmpty or water-filled rigid plastic and metal pipes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermostat\u003c\/td\u003e\n\u003ctd\u003eIntegrated adjustable digital heating thermostat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Sensor\u003c\/td\u003e\n\u003ctd\u003eRemote pipe sensor with approximately 6.6 ft \/ 200 cm lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Lead\u003c\/td\u003e\n\u003ctd\u003eApproximately 3 ft \/ 90 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Setting Range\u003c\/td\u003e\n\u003ctd\u003e36–140°F \/ 1–60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Display Range\u003c\/td\u003e\n\u003ctd\u003e-22–158°F \/ -30–70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Units\u003c\/td\u003e\n\u003ctd\u003eSelectable °F \/ °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Set Temperature\u003c\/td\u003e\n\u003ctd\u003e37°F \/ 3°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefault Upper Limit\u003c\/td\u003e\n\u003ctd\u003e+10°F \/ +5°C above the set temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjustable Upper Limit\u003c\/td\u003e\n\u003ctd\u003e1–20°F \/ 1–10°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimer\u003c\/td\u003e\n\u003ctd\u003e0–10 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Calibration\u003c\/td\u003e\n\u003ctd\u003eAdjustable within ±9°F \/ ±5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForced Heating Mode\u003c\/td\u003e\n\u003ctd\u003eYes; allows continuous heating regardless of the detected temperature until forced mode is exited\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Status Indicator\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Installation Temperature\u003c\/td\u003e\n\u003ctd\u003e-4°F \/ -20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Temperature Limit\u003c\/td\u003e\n\u003ctd\u003eDo not install on pipes exposed to temperatures above 140°F \/ 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Protection\u003c\/td\u003e\n\u003ctd\u003eUse a properly grounded 120V outlet protected by a GFCI outlet or GFCI\/EGFPD breaker as required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFault Monitoring\u003c\/td\u003e\n\u003ctd\u003eE1 external temperature-probe fault prompt and H1 controller overtemperature protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Contents\u003c\/td\u003e\n\u003ctd\u003eThermostatic heating cable, instruction manual, end seal, self-adhesive tape, and aluminum foil tape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e1 year from date of purchase, subject to warranty terms and proper installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cdiv class=\"yd-notice-box\"\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature control note:\u003c\/strong\u003e A smaller upper-limit setting provides tighter temperature control but increases switching frequency. A larger upper limit reduces on\/off cycling but allows a wider temperature range.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation\u003c\/h3\u003e\n\u003cdiv class=\"yd-product-section\"\u003e\n\u003ch4\u003eBefore Installation\u003c\/h4\u003e\n\u003cdiv class=\"yd-check-grid\"\u003e\n\u003cspan\u003eConfirm 120V power\u003c\/span\u003e\n\u003cspan\u003eConfirm pipe material and diameter\u003c\/span\u003e\n\u003cspan\u003eCalculate the required cable length\u003c\/span\u003e\n\u003cspan\u003eInspect the complete cable jacket\u003c\/span\u003e\n\u003cspan\u003eClean and dry the pipe\u003c\/span\u003e\n\u003cspan\u003eRemove sharp edges and combustible materials\u003c\/span\u003e\n\u003cspan\u003eIdentify the coldest sensor location\u003c\/span\u003e\n\u003cspan\u003ePrepare suitable pipe insulation\u003c\/span\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eBasic Installation Sequence\u003c\/h4\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect power and inspect the heating cable, thermostat, sensor, power cord, and pipe before installation.\u003c\/li\u003e\n\u003cli\u003eAttach the temperature sensor directly to the coldest part of the pipe surface, such as a colder exposed section or an area near a valve.\u003c\/li\u003e\n\u003cli\u003eSecure the sensor firmly so it reads the pipe temperature rather than surrounding air temperature.\u003c\/li\u003e\n\u003cli\u003eInstall the heating cable along the pipe. Use a straight run when the selected cable length matches the pipe length, or use the approved spiral or doubled-back method when additional cable coverage is required.\u003c\/li\u003e\n\u003cli\u003eKeep the heating cable on the opposite side of the pipe from the temperature sensor. Do not allow the sensor probe to contact the heating cable.\u003c\/li\u003e\n\u003cli\u003eSecure the cable using suitable fiberglass tape, electrical tape, aluminum foil tape, or properly installed cable ties that will not damage the cable jacket.\u003c\/li\u003e\n\u003cli\u003eCover the pipe, heating cable, and sensor probe with suitable non-flammable pipe insulation. Keep the sensor wire positioned so it does not contact the heating cable.\u003c\/li\u003e\n\u003cli\u003eUse a waterproof outer wrap where required to keep the insulation dry.\u003c\/li\u003e\n\u003cli\u003eConnect the thermostat to a properly grounded, ground-fault-protected 120V outlet in a dry, well-ventilated location.\u003c\/li\u003e\n\u003cli\u003eTurn on the thermostat, verify the displayed pipe temperature, and confirm the operating settings before winter use.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch4\u003eInsulation Requirements\u003c\/h4\u003e\n\u003cdiv class=\"yd-install-grid\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eStandard Insulation\u003c\/strong\u003e\n\u003cspan\u003eUse at least 1\/2 in \/ 12.7 mm fiberglass or equivalent non-flammable pipe insulation.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eSevere Cold\u003c\/strong\u003e\n\u003cspan\u003eFor ambient temperatures at or below -20°F \/ -29°C, the manual specifies 1 in \/ 25.4 mm pipe insulation.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eKeep Insulation Dry\u003c\/strong\u003e\n\u003cspan\u003eUse a waterproof outer layer or vapor barrier where moisture may reach the insulation.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eProtect the Sensor\u003c\/strong\u003e\n\u003cspan\u003eCover the sensor probe with the pipe insulation while keeping it separated from the heating cable.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"yd-alert-box\"\u003e\n\u003cp\u003e\u003cstrong\u003eSensor placement is critical.\u003c\/strong\u003e Mount the probe directly on the coldest protected pipe section. Do not place it against the heating cable. Incorrect placement can cause inaccurate readings and may turn heating off too early or keep it running longer than necessary.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eCable and Controller Safety\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDo not energize a visibly damaged heating cable.\u003c\/li\u003e\n\u003cli\u003eDo not install below the minimum installation temperature of -4°F \/ -20°C.\u003c\/li\u003e\n\u003cli\u003eDo not install the cable on pipes hotter than 140°F \/ 60°C.\u003c\/li\u003e\n\u003cli\u003eDo not crush, sharply bend, or damage the heating-cable jacket during installation.\u003c\/li\u003e\n\u003cli\u003eDo not disassemble, modify, or repair the thermostat.\u003c\/li\u003e\n\u003cli\u003eIf heating-cable trimming is required, the cut end must be sealed with a proper self-regulating cable end seal or suitable heat-shrink termination before the cable is energized.\u003c\/li\u003e\n\u003cli\u003eKeep the controller, plug, and electrical connections dry and away from standing water.\u003c\/li\u003e\n\u003cli\u003eIf an extension cord is unavoidable, use a properly sized, grounded outdoor-rated cord suitable for the electrical load.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv class=\"yd-notice-box\"\u003e\n\u003cp\u003eThe thermostat is factory set to 37°F \/ 3°C with a +10°F \/ +5°C upper limit. For standard freeze protection, adjustment is normally unnecessary unless the installation requires a different operating temperature.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp\u003eFor additional guidance on thermostat control and sensor placement, see \u003ca href=\"https:\/\/yelodeer.com\/blogs\/knowledge-center\/self-regulating-heat-tape-thermostat\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eDoes Self-Regulating Heat Tape Need a Thermostat? →\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cdiv class=\"yd-product-section yd-faq-section\"\u003e\n\u003ch4\u003eFrequently Asked Questions\u003c\/h4\u003e\n\n\u003cdetails\u003e\n\u003csummary\u003eHow is this different from the yellow pipe heat cable without a thermostat?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe yellow basic version has no built-in thermostat and begins heating whenever it receives power. This upgraded model adds an integrated digital thermostat and 6.6 ft remote pipe sensor, allowing automatic temperature-based control without purchasing a separate thermostat.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails\u003e\n\u003csummary\u003eWhat temperature does the thermostat use by default?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe factory setpoint is 37°F \/ 3°C with a default upper limit of +10°F \/ +5°C. With these settings, heating starts when the sensed temperature falls below 37°F \/ 3°C and stops after it rises above approximately 47°F \/ 8°C.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails\u003e\n\u003csummary\u003eCan I change the thermostat temperature?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eYes. The temperature setpoint is adjustable from 36°F to 140°F \/ 1°C to 60°C. The upper temperature limit can also be adjusted from 1°F to 20°F \/ 1°C to 10°C above the selected setpoint.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails\u003e\n\u003csummary\u003eDoes self-regulating heat cable turn itself completely off?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eSelf-regulating technology changes heat output along the cable as temperature changes, but self-regulation alone does not mean the cable fully switches off. On this model, the integrated thermostat provides the separate temperature-based on\/off control.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails\u003e\n\u003csummary\u003eWhere should I install the temperature sensor?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eAttach the sensor directly to the coldest protected part of the pipe. Keep it firmly against the pipe surface and separate from the heating cable. The sensor and heating cable should not directly touch because heat from the cable can cause an inaccurate temperature reading.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails\u003e\n\u003csummary\u003eWhat pipe sizes and materials can I use it on?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe instruction manual specifies empty or water-filled rigid plastic and metal pipes from 1\/2 in to 2 in diameter. This is an external pipe heating cable and should not be installed inside the pipe.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails\u003e\n\u003csummary\u003eCan the heating cable be shortened?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe manual allows trimming only when necessary. Any cut heating-cable end must be properly sealed with a professional self-regulating cable end seal or suitable heat-shrink termination before power is connected. An end seal is included with the product.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails\u003e\n\u003csummary\u003eWhat are the timer and Forced Heating functions?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe timer can be set from 0 to 10 hours for timed thermostat operation. Forced Heating mode keeps the cable heating regardless of the detected temperature until forced mode is exited. It is intended as a backup when the sensor is inaccurate or faulty, or for special situations where continuous heating is intentionally required.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eGuides\u003c\/h3\u003e\n\u003cdiv class=\"yd-product-section\"\u003e\n\u003ch4\u003eHelpful Pipe Heating Guides\u003c\/h4\u003e\n\n\u003cp\u003eFor a clear explanation of self-regulating heat output, thermostat power control, and correct pipe-sensor placement, read:\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/yelodeer.com\/blogs\/knowledge-center\/self-regulating-heat-tape-thermostat\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eDoes Self-Regulating Heat Tape Need a Thermostat? →\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\n\u003cp\u003eFor pipe preparation, cable placement, insulation, electrical protection, and general freeze-protection planning, read:\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/yelodeer.com\/blogs\/knowledge-center\/how-heatingcable-work\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eHow Does Heat Tape for Pipes Work? →\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\n\u003cdiv class=\"yd-notice-box\"\u003e\n\u003cp\u003e\u003cstrong\u003eBefore selecting a cable length:\u003c\/strong\u003e Confirm the pipe material, diameter, total freeze-prone length, lowest expected ambient temperature, installation layout, insulation, and outlet location. Use the cable-length recommendation table in the product instruction manual for final sizing.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp\u003eIf you are unsure whether this thermostatic pipe heat cable fits your installation, email \u003ca href=\"mailto:yelodeer@yelodeer.com\"\u003e\u003cstrong\u003eyelodeer@yelodeer.com\u003c\/strong\u003e\u003c\/a\u003e with the pipe material, diameter, protected length, lowest winter temperature, installation photos, and insulation plan.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"YeloDeer","offers":[{"title":"3 ft","offer_id":45237243543793,"sku":"PGY-3-C","price":33.99,"currency_code":"USD","in_stock":true},{"title":"6 ft","offer_id":45237243576561,"sku":"PGY-6-C","price":35.99,"currency_code":"USD","in_stock":true},{"title":"9 ft","offer_id":45237243609329,"sku":"PGY-9-C","price":37.99,"currency_code":"USD","in_stock":true},{"title":"12 ft","offer_id":45237243642097,"sku":"PGY-12-C","price":39.99,"currency_code":"USD","in_stock":true},{"title":"15 ft","offer_id":45237243674865,"sku":"PGY-15-C","price":41.99,"currency_code":"USD","in_stock":true},{"title":"18 ft","offer_id":45237243707633,"sku":"PGY-18-C","price":43.99,"currency_code":"USD","in_stock":true},{"title":"24 ft","offer_id":45237243740401,"sku":"PGY-24-C","price":47.99,"currency_code":"USD","in_stock":true},{"title":"30 ft","offer_id":45237243773169,"sku":"PGY-30-C","price":51.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0701\/2836\/9905\/files\/PGY-C_1.jpg?v=1788318221","url":"https:\/\/yelodeer.com\/products\/self-regulating-pipe-heat-cable-digital-thermostat","provider":"YeloDeer","version":"1.0","type":"link"}