{"product_id":"manual-electric-floor-heating-thermostat","title":"Manual Electric Floor Heating Thermostat with Floor Sensor","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cdiv class=\"yd-product-section\"\u003e\n\u003cp\u003e\u003cstrong\u003eSimple Manual Control for Electric Floor Heating\u003c\/strong\u003e\u003c\/p\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0701\/2836\/9905\/files\/EU19_A_1.jpg?v=1789958291\" alt=\"\"\u003e\n\u003cp\u003eThis non-programmable electric floor heating thermostat provides straightforward rotary temperature control for compatible 120V and 240V floor heating cables and mats. It uses the supplied floor sensor to monitor floor temperature and automatically cycles the heating system to maintain the selected setting.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0701\/2836\/9905\/files\/EU19_A_4.jpg?v=1789958291\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"yd-alert-box\"\u003e\n\u003cp\u003e\u003cstrong\u003eFloor temperature control only:\u003c\/strong\u003e This thermostat does not measure or control room air temperature. Choose it when your application requires direct floor-sensor control rather than room-temperature control.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch4\u003eQuick Fit Check\u003c\/h4\u003e\n\u003cdiv class=\"yd-decision-strip\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eElectric Floor Heating\u003c\/strong\u003e \u003cspan\u003eDesigned for indoor electric floor heating cables and heating mats.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e120V \/ 240V\u003c\/strong\u003e \u003cspan\u003eCompatible with properly wired 120V or 240V AC floor heating systems.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e15A Maximum Load\u003c\/strong\u003e \u003cspan\u003eRated for up to 15A resistive load. A properly rated contactor is required when the connected load exceeds this rating.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eFloor Sensor Only\u003c\/strong\u003e \u003cspan\u003eUses the supplied 10 kOhm NTC floor sensor for temperature control.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eWhat Is Included?\u003c\/h4\u003e\n\u003cdiv class=\"yd-do-dont-grid\"\u003e\n\u003cdiv class=\"yd-do-card\"\u003e\n\u003cstrong\u003eIncluded Floor Sensor\u003c\/strong\u003e \u003cspan\u003eThe thermostat is supplied with the floor sensor required for temperature control. The sensor is rated 10 kOhm NTC at 77°F \/ 25°C.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"yd-dont-card\"\u003e\n\u003cstrong\u003eNo Built-In GFCI\u003c\/strong\u003e \u003cspan\u003eThis thermostat does not include GFCI protection. Use a GFCI-protected circuit where required by electrical code or the floor heating system manufacturer.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eBefore Ordering\u003c\/h4\u003e\n\u003cdiv class=\"yd-check-grid\"\u003e\n\u003cspan\u003eYour system is electric floor heating\u003c\/span\u003e \u003cspan\u003eSystem voltage is 120V or 240V AC\u003c\/span\u003e \u003cspan\u003eTotal resistive load does not exceed 15A\u003c\/span\u003e \u003cspan\u003eYou will use the supplied floor sensor\u003c\/span\u003e \u003cspan\u003eYour flooring is approved for radiant floor heating\u003c\/span\u003e \u003cspan\u003eRequired GFCI protection is provided separately\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"yd-notice-box\"\u003e\n\u003cp\u003e\u003cstrong\u003eFlooring matters:\u003c\/strong\u003e Suitable floor finishes can include tile, stone, laminate, engineered wood, and similar materials approved for radiant floor heating. Always follow the flooring manufacturer's maximum allowable floor temperature.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"yd-alert-box\"\u003e\n\u003cp\u003e\u003cstrong\u003eLine-voltage installation:\u003c\/strong\u003e Installation and wiring must be performed by a qualified electrician and comply with the National Electrical Code, Canadian Electrical Code, and applicable local electrical codes. Disconnect power at the breaker before installation or service.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0701\/2836\/9905\/files\/EU19_A_2.jpg?v=1789958292\" alt=\"\"\u003e\u003c\/p\u003e\n\u003ch4\u003ePrefer Smart or Programmable Control?\u003c\/h4\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0701\/2836\/9905\/files\/EU19_A_3.jpg?v=1789958291\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eThis model is intentionally simple: rotary control, no programming, and floor-sensor-only operation. If you need WiFi, app control, or programmable scheduling, compare the \u003ca href=\"https:\/\/yelodeer.com\/products\/yelodeer-smart-wifi-thermostat-floor-heating\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eYeloDeer Smart WiFi Electric Floor Heating Thermostat →\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv class=\"yd-product-section\"\u003e\n\u003ch4\u003eRecommended Applications\u003c\/h4\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0701\/2836\/9905\/files\/EU19_A_6.jpg?v=1789958292\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"yd-category-grid\"\u003e\n\u003cdiv class=\"yd-category-card\"\u003e\n\u003cstrong\u003eElectric Floor Heating\u003c\/strong\u003e\n\u003cdiv class=\"yd-mini-tags\"\u003e\n\u003cspan\u003eHeating Cables\u003c\/span\u003e \u003cspan\u003eHeating Mats\u003c\/span\u003e \u003cspan\u003eRadiant Floor Warming\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"yd-category-card\"\u003e\n\u003cstrong\u003eCompatible Floor Finishes\u003c\/strong\u003e\n\u003cdiv class=\"yd-mini-tags\"\u003e\n\u003cspan\u003eTile\u003c\/span\u003e \u003cspan\u003eStone\u003c\/span\u003e \u003cspan\u003eLaminate\u003c\/span\u003e \u003cspan\u003eEngineered Wood\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"yd-category-card\"\u003e\n\u003cstrong\u003eSimple Control Projects\u003c\/strong\u003e\n\u003cdiv class=\"yd-mini-tags\"\u003e\n\u003cspan\u003eManual Dial\u003c\/span\u003e \u003cspan\u003eNon-Programmable\u003c\/span\u003e \u003cspan\u003eFloor Sensor Control\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eCompatibility Requirements\u003c\/h4\u003e\n\u003ctable class=\"yd-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating System\u003c\/td\u003e\n\u003ctd\u003eIndoor electric floor heating cable or heating mat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eExternal floor sensor only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Voltage\u003c\/td\u003e\n\u003ctd\u003e120V or 240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Thermostat Load\u003c\/td\u003e\n\u003ctd\u003e15A resistive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFloor Sensor\u003c\/td\u003e\n\u003ctd\u003eUse only the sensor supplied with this thermostat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlooring\u003c\/td\u003e\n\u003ctd\u003eFloor finish must be approved by its manufacturer for radiant floor heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eDo Not Use When\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eYou need the thermostat to measure or control room air temperature.\u003c\/li\u003e\n\u003cli\u003eThe connected floor heating load exceeds 15A unless a properly rated contactor is incorporated into the system.\u003c\/li\u003e\n\u003cli\u003eThe installation requires built-in GFCI protection; this thermostat does not provide it.\u003c\/li\u003e\n\u003cli\u003eYou intend to substitute an unverified third-party floor sensor.\u003c\/li\u003e\n\u003cli\u003eThe thermostat would be exposed to water spray, excessive moisture, direct sunlight, corrosive environments, or excessive heat.\u003c\/li\u003e\n\u003cli\u003eThe installation is outdoors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"yd-notice-box\"\u003e\n\u003cp\u003eFor bathrooms, kitchens, laundry rooms, or other damp locations, the thermostat must be protected from water splashing and excessive humidity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv class=\"yd-product-section\"\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable class=\"yd-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eNon-programmable electric floor heating thermostat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eManual rotary dial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Sensor\u003c\/td\u003e\n\u003ctd\u003eFloor sensor only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e120\/240 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Rating\u003c\/td\u003e\n\u003ctd\u003e15A resistive load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFloor Sensor\u003c\/td\u003e\n\u003ctd\u003e10 kOhm NTC at 77°F \/ 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Setting Range\u003c\/td\u003e\n\u003ctd\u003e40°F–100°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Wire Size\u003c\/td\u003e\n\u003ctd\u003e14–12 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e14°F–122°F \/ -10°C–50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Class\u003c\/td\u003e\n\u003ctd\u003eIP21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-In GFCI\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Environment\u003c\/td\u003e\n\u003ctd\u003eIndoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgrammable\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eTerminal Functions\u003c\/h4\u003e\n\u003ctable class=\"yd-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eL1 (LINE)\u003c\/td\u003e\n\u003ctd\u003eLine input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eL2 \/ N (LINE)\u003c\/td\u003e\n\u003ctd\u003eNeutral for 120V; Line 2 for 240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eL1 (LOAD)\u003c\/td\u003e\n\u003ctd\u003eHeating cable line output, maximum 15A resistive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eL2 \/ N (LOAD)\u003c\/td\u003e\n\u003ctd\u003eLoad return: Neutral for 120V; Line 2 for 240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNTC\u003c\/td\u003e\n\u003ctd\u003eExternal floor sensor connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv class=\"yd-alert-box\"\u003e\n\u003cp\u003e\u003cstrong\u003eImportant for 240V systems:\u003c\/strong\u003e In a 240V split-phase installation, the L2 \/ N terminal is used as Line 2, not Neutral. Do not identify conductors by color alone; the circuit must be correctly verified before wiring.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch4\u003eOperation\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRotate the knob clockwise from OFF to turn the thermostat on and select the desired floor temperature.\u003c\/li\u003e\n\u003cli\u003eRotate the knob fully back to OFF to turn the thermostat off.\u003c\/li\u003e\n\u003cli\u003eThe indicator light turns on when the thermostat is supplying power to the heating system.\u003c\/li\u003e\n\u003cli\u003eThe indicator turns off when heating is not required or the thermostat is set to OFF.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTypical floor comfort temperatures may fall between 75°F and 85°F, but the correct setting depends on the flooring material, room insulation, occupant preference, and the flooring manufacturer's temperature limits.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eInstallation\u003c\/h3\u003e\n\u003cdiv class=\"yd-product-section\"\u003e\n\u003cdiv class=\"yd-alert-box\"\u003e\n\u003cp\u003e\u003cstrong\u003eDisconnect power before wiring.\u003c\/strong\u003e This thermostat controls line-voltage equipment. Installation must be performed by a qualified electrician and comply with applicable national and local electrical codes.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch4\u003eBefore Installation\u003c\/h4\u003e\n\u003cdiv class=\"yd-check-grid\"\u003e\n\u003cspan\u003eConfirm 120V or 240V system voltage\u003c\/span\u003e \u003cspan\u003eConfirm total floor heating load is 15A or less\u003c\/span\u003e \u003cspan\u003eConfirm required GFCI protection\u003c\/span\u003e \u003cspan\u003eUse the supplied floor sensor\u003c\/span\u003e \u003cspan\u003eReview the heating system instructions\u003c\/span\u003e \u003cspan\u003eReview flooring temperature limits\u003c\/span\u003e\n\u003c\/div\u003e\n\u003ch4\u003e1. Position the Floor Sensor\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRoute the supplied floor sensor from the thermostat wall box into the heated floor area.\u003c\/li\u003e\n\u003cli\u003ePlace the sensor probe midway between two adjacent heating cables.\u003c\/li\u003e\n\u003cli\u003eRun the sensor probe parallel to the heating cables.\u003c\/li\u003e\n\u003cli\u003eExtend the probe at least 12 in \/ 30 cm into the heated area.\u003c\/li\u003e\n\u003cli\u003eDo not allow the sensor probe to touch, cross, or overlap a heating cable.\u003c\/li\u003e\n\u003cli\u003eInstall the sensor according to the floor heating system manufacturer's instructions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"yd-alert-box\"\u003e\n\u003cp\u003e\u003cstrong\u003eSensor placement is critical:\u003c\/strong\u003e Incorrect placement can cause inaccurate temperature sensing or poor heating performance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch4\u003e2. Sensor Conduit or Protective Sleeve\u003c\/h4\u003e\n\u003cp\u003eA sensor conduit or protective sleeve may be used when required by local code or recommended by the heating system manufacturer.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSeal the floor end before applying thinset, mortar, self-leveling compound, or concrete.\u003c\/li\u003e\n\u003cli\u003eFeed the sensor wire through the conduit until the probe reaches the sealed end.\u003c\/li\u003e\n\u003cli\u003eIf no conduit is used, secure the sensor directly to the subfloor as instructed by the heating system manufacturer.\u003c\/li\u003e\n\u003cli\u003eDo not run the floor sensor wire and heating power wires in the same conduit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e3. Thermostat Location\u003c\/h4\u003e\n\u003cp\u003eInstall the thermostat on an interior wall approximately 5 ft \/ 1.5 m above the finished floor.\u003c\/p\u003e\n\u003cdiv class=\"yd-do-dont-grid\"\u003e\n\u003cdiv class=\"yd-do-card\"\u003e\n\u003cstrong\u003eChoose a Protected Indoor Location\u003c\/strong\u003e \u003cspan\u003eUse an interior wall location suitable for the electrical box and floor sensor route.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"yd-dont-card\"\u003e\n\u003cstrong\u003eAvoid Problem Locations\u003c\/strong\u003e \u003cspan\u003eDo not install where exposed to direct sunlight, drafts, excessive moisture, exterior walls, additional heat sources, or water spray.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003e4. Wiring\u003c\/h4\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0701\/2836\/9905\/files\/EU19_A_5.jpg?v=1789958291\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"yd-install-grid\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e120V System\u003c\/strong\u003e \u003cspan\u003eL1 is the live input and L2 \/ N is Neutral. Typical conductor colors may be black for Live and white for Neutral.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e240V System\u003c\/strong\u003e \u003cspan\u003eL1 is Line 1 and L2 \/ N is Line 2. In a 240V split-phase system, L2 \/ N is not Neutral.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eHeating Load\u003c\/strong\u003e \u003cspan\u003eConnect the heating system to the designated LOAD terminals. Do not exceed the 15A resistive rating.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eFloor Sensor\u003c\/strong\u003e \u003cspan\u003eConnect the supplied external floor sensor to the NTC terminals.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eGrounding\u003c\/strong\u003e \u003cspan\u003eConnect grounding conductors according to local code and the floor heating system manufacturer's instructions.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eHigh Loads\u003c\/strong\u003e \u003cspan\u003eIf the connected heating load exceeds the thermostat rating, use a properly rated contactor.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003e5. Before Energizing\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm all wiring is complete and secure.\u003c\/li\u003e\n\u003cli\u003eConfirm the floor sensor has been correctly installed.\u003c\/li\u003e\n\u003cli\u003eConfirm the heating circuit has required GFCI protection.\u003c\/li\u003e\n\u003cli\u003eDo not energize the floor heating system until flooring, mortar, or other installation materials have cured according to their manufacturer's instructions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor additional information on identifying 120V and 240V floor heating circuits and avoiding common wiring mistakes, read the \u003ca href=\"https:\/\/yelodeer.com\/blogs\/electric-floor-heating-thermostats\/120v-vs-240v-floor-heating-thermostat-wiring-what-homeowners-should-know\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003e120V vs. 240V Floor Heating Thermostat Wiring Guide →\u003c\/strong\u003e\u003c\/a\u003e. Always follow the EU19A wiring diagram for the final thermostat connections.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cdiv class=\"yd-product-section yd-faq-section\"\u003e\n\u003ch4\u003eFrequently Asked Questions\u003c\/h4\u003e\n\u003cdetails\u003e\n\u003csummary\u003eIs this thermostat for electric floor heating?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eYes. It is designed for indoor electric floor heating systems using compatible heating cables or heating mats.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eDoes it control room temperature?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eNo. This thermostat uses the supplied floor sensor and controls floor temperature only. It does not measure or regulate room air temperature.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan I use it with both 120V and 240V floor heating?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eYes. The thermostat is rated for 120\/240 VAC, 50\/60 Hz. The heating system and power supply must be correctly matched, and the connected load must remain within the 15A resistive rating.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eDoes the thermostat include built-in GFCI protection?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eNo. Use a GFCI-protected circuit where required by local electrical code or by the heating system manufacturer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan I reuse a different floor sensor?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eNo substitute sensor is specified for this model. Use only the floor sensor supplied with the thermostat. If it is damaged, missing, or not operating correctly, contact YeloDeer for a replacement.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhere should the floor sensor be installed?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003ePlace the probe midway between two adjacent heating cables, parallel to the cables, and at least 12 in \/ 30 cm into the heated area. The probe must not touch, cross, or overlap a heating cable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat if my floor heating system draws more than 15A?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eDo not connect a load above the thermostat's 15A resistive rating directly to the thermostat. The manual specifies using a properly rated contactor when the heating load exceeds the thermostat rating.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat does the indicator light mean?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe indicator is on when the thermostat is supplying power to the floor heating system. It turns off when heating is not required or when the thermostat is set to OFF.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003ch3\u003eGuides\u003c\/h3\u003e\n\u003cdiv class=\"yd-product-section\"\u003e\n\u003ch4\u003ePre-Installation Checklist\u003c\/h4\u003e\n\u003cdiv class=\"yd-check-grid\"\u003e\n\u003cspan\u003eVerify 120V or 240V supply\u003c\/span\u003e \u003cspan\u003eCalculate total heating amperage\u003c\/span\u003e \u003cspan\u003eConfirm GFCI protection\u003c\/span\u003e \u003cspan\u003ePlan the floor sensor location\u003c\/span\u003e \u003cspan\u003eCheck flooring temperature limits\u003c\/span\u003e \u003cspan\u003eHave a qualified electrician complete the wiring\u003c\/span\u003e\n\u003c\/div\u003e\n\u003ch4\u003eRelated YeloDeer Resource\u003c\/h4\u003e\n\u003cp\u003eFor help understanding the difference between 120V and 240V floor heating wiring, conductor identification, grounding, and common installation mistakes, see the \u003ca href=\"https:\/\/yelodeer.com\/blogs\/electric-floor-heating-thermostats\/120v-vs-240v-floor-heating-thermostat-wiring-what-homeowners-should-know\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003e120V vs. 240V Floor Heating Thermostat Wiring Guide →\u003c\/strong\u003e\u003c\/a\u003e.\u003c\/p\u003e\n\u003cdiv class=\"yd-notice-box\"\u003e\n\u003cp\u003e\u003cstrong\u003eUse the product manual for final installation.\u003c\/strong\u003e Wiring terminal names and specifications vary between thermostat models. Follow the EU19A wiring diagram and the floor heating manufacturer's instructions for the actual installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch4\u003eWarranty\u003c\/h4\u003e\n\u003cp\u003eThe thermostat includes a 1-year limited warranty for quality-related issues, limited to the product itself. The warranty does not cover damage caused by improper installation, misuse or abuse, accidents, unauthorized modification, or failure to follow the product instructions.\u003c\/p\u003e\n\u003cp\u003eFor compatibility, installation, replacement sensor, or technical support questions, contact \u003ca href=\"mailto:yelodeer@yelodeer.com\"\u003e\u003cstrong\u003eyelodeer@yelodeer.com\u003c\/strong\u003e\u003c\/a\u003e with your system voltage, connected load, floor heating system information, wiring photos, and a description of the issue.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"YeloDeer","offers":[{"title":"Default Title","offer_id":48673674887409,"sku":"EU19-1pc","price":34.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0701\/2836\/9905\/files\/EU19_1.jpg?v=1788316945","url":"https:\/\/yelodeer.com\/products\/manual-electric-floor-heating-thermostat","provider":"YeloDeer","version":"1.0","type":"link"}