{"product_id":"flat-roof-drain-deicing-system","title":"Roof Drain De-Icing System for Flat \u0026 Low-Slope Roofs (FRDDS)","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cdiv class=\"yd-product-section\"\u003e\n\u003cp\u003e\u003cstrong\u003eTargeted Freeze Protection for Internal Drains on Flat and Low-Slope Roofs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe YeloDeer Flat Roof Drain De-Icing System is designed to help keep internal roof drains open during winter freeze-thaw conditions. Instead of heating the entire roof, the system concentrates self-regulating heat around the drain opening and extends part of the heating cable into the drainage path where localized ice blockage can prevent meltwater from leaving the roof.\u003c\/p\u003e\n\u003cp\u003eThe complete 120V kit combines a 50 ft self-regulating heating cable with a center aluminum ring and six grooved aluminum panels. The aluminum assembly organizes cable placement around the drain while helping distribute heat across the freeze-prone drainage area.\u003c\/p\u003e\n\u003cp\u003eDesigned for commercial buildings, multifamily properties, warehouses, schools, facilities, and other flat or low-slope roofs with internal drainage systems.\u003c\/p\u003e\n\u003ch4\u003eQuick Fit Snapshot\u003c\/h4\u003e\n\u003cdiv class=\"yd-decision-strip\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eDrain Compatibility\u003c\/strong\u003e \u003cspan\u003eDesigned for compatible internal roof drains up to 14 in \/ 355 mm.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e120V Complete Kit\u003c\/strong\u003e \u003cspan\u003eIncludes a 50 ft self-regulating heating cable and 25 ft power cord.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eTargeted Drain Heating\u003c\/strong\u003e \u003cspan\u003ePositions heat around the drain opening and allows cable to extend into the drainage path.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eCSA Certified Cable\u003c\/strong\u003e \u003cspan\u003eThe heating cable supplied with the Complete Kit is CSA certified.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eKey Benefits\u003c\/h4\u003e\n\u003cdiv class=\"yd-scenario-grid\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eTargets the Critical Drain Area\u003c\/strong\u003e \u003cspan\u003eConcentrates heat where localized freezing can interrupt drainage instead of attempting to melt snow across the entire roof.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eOrganized Cable Positioning\u003c\/strong\u003e \u003cspan\u003eSix grooved aluminum panels hold the heating cable in a planned layout around the drain opening.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eFlexible Six-Panel Layout\u003c\/strong\u003e \u003cspan\u003eUse all six panels in an open area, or omit one or more when a wall, parapet, curb, or rooftop obstruction limits space.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eAdjustable Heating Coverage\u003c\/strong\u003e \u003cspan\u003eAvailable cable can extend into the drain or toward a localized icing area when additional targeted coverage is required.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eSuitable For\u003c\/h4\u003e\n\u003cdiv class=\"yd-category-grid\"\u003e\n\u003cdiv class=\"yd-category-card\"\u003e\n\u003cstrong\u003eCommercial Buildings\u003c\/strong\u003e\n\u003cdiv class=\"yd-mini-tags\"\u003e\n\u003cspan\u003eOffice Buildings\u003c\/span\u003e \u003cspan\u003eRetail Buildings\u003c\/span\u003e \u003cspan\u003eHotels\u003c\/span\u003e \u003cspan\u003eShopping Centers\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"yd-category-card\"\u003e\n\u003cstrong\u003eIndustrial \u0026amp; Facility Roofs\u003c\/strong\u003e\n\u003cdiv class=\"yd-mini-tags\"\u003e\n\u003cspan\u003eWarehouses\u003c\/span\u003e \u003cspan\u003eManufacturing\u003c\/span\u003e \u003cspan\u003eDistribution Centers\u003c\/span\u003e \u003cspan\u003eUtility Buildings\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"yd-category-card\"\u003e\n\u003cstrong\u003eInstitutional Properties\u003c\/strong\u003e\n\u003cdiv class=\"yd-mini-tags\"\u003e\n\u003cspan\u003eSchools\u003c\/span\u003e \u003cspan\u003eUniversities\u003c\/span\u003e \u003cspan\u003eHospitals\u003c\/span\u003e \u003cspan\u003eMunicipal Buildings\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"yd-category-card\"\u003e\n\u003cstrong\u003eFreeze-Prone Roof Drains\u003c\/strong\u003e\n\u003cdiv class=\"yd-mini-tags\"\u003e\n\u003cspan\u003eFlat Roofs\u003c\/span\u003e \u003cspan\u003eLow-Slope Roofs\u003c\/span\u003e \u003cspan\u003eInternal Drains\u003c\/span\u003e \u003cspan\u003eFreeze-Thaw Areas\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eWhat Is Included\u003c\/h4\u003e\n\u003cdiv class=\"yd-check-grid\"\u003e\n\u003cspan\u003e1 center aluminum spacer ring\u003c\/span\u003e \u003cspan\u003e6 grooved aluminum panels\u003c\/span\u003e \u003cspan\u003e50 ft self-regulating heating cable\u003c\/span\u003e \u003cspan\u003e25 ft power cord\u003c\/span\u003e \u003cspan\u003e120V plug-in power configuration\u003c\/span\u003e \u003cspan\u003eInstallation instructions\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eNot included:\u003c\/strong\u003e roof drain dome or strainer, roof de-icing controller, required GFCI\/GFEP protection, junction box, or site-specific electrical and mounting components.\u003c\/p\u003e\n\u003ch4\u003eImportant Before Ordering\u003c\/h4\u003e\n\u003cdiv class=\"yd-alert-box\"\u003e\n\u003cp\u003e\u003cstrong\u003eThis is a targeted roof drain freeze-protection system—not a whole-roof snow-melting system.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBefore ordering, confirm that your roof is flat or low-slope, uses an internal drain, and has enough space for the aluminum assembly. The center assembly is designed for compatible drains up to 14 in \/ 355 mm.\u003c\/p\u003e\n\u003cp\u003eThe standard Complete Kit uses 120V power and includes 50 ft of heating cable. Required GFCI\/GFEP electrical protection must be provided, and the heating cable must be positioned so it does not obstruct the drain opening or interfere with water flow.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"yd-check-grid\"\u003e\n\u003cspan\u003eInternal roof drain application\u003c\/span\u003e \u003cspan\u003eDrain size is 14 in \/ 355 mm or smaller\u003c\/span\u003e \u003cspan\u003e50 ft cable is suitable for the planned route\u003c\/span\u003e \u003cspan\u003eCompatible 120V power is available\u003c\/span\u003e \u003cspan\u003eRequired GFCI\/GFEP protection can be provided\u003c\/span\u003e \u003cspan\u003eCable can enter the drain without blocking water flow\u003c\/span\u003e \u003cspan\u003eRoof and drain area are suitable for installation\u003c\/span\u003e \u003cspan\u003eProfessional installation support is available when required\u003c\/span\u003e\n\u003c\/div\u003e\n\u003ch4\u003eNeed a Custom Roof De-Icing Layout?\u003c\/h4\u003e\n\u003cp\u003eIf your project requires a different cable length, 240V power, hardwired installation, multiple roof drains, bulk cable, or an aluminum assembly without the standard heating cable, review the \u003ca href=\"https:\/\/yelodeer.com\/pages\/project-consultation-for-freeze-protection-solutions\"\u003e\u003cstrong\u003eYeloDeer Project Consultation\u003c\/strong\u003e\u003c\/a\u003e page before ordering.\u003c\/p\u003e\n\u003cp\u003eQualified installers planning custom cable lengths can also view the \u003ca href=\"https:\/\/yelodeer.com\/products\/yelodeer-cut-to-length-roof-deicing-cable\"\u003e\u003cstrong\u003eYeloDeer Bulk Cut-to-Length Self-Regulating Heat Trace Cable\u003c\/strong\u003e\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv class=\"yd-product-section\"\u003e\n\u003ch4\u003eRecommended Applications\u003c\/h4\u003e\n\u003cp\u003eThis roof drain de-icing system is designed for flat and low-slope roofs where meltwater converges at an internal drain and repeated winter freezing can restrict the drainage path.\u003c\/p\u003e\n\u003cdiv class=\"yd-category-grid\"\u003e\n\u003cdiv class=\"yd-category-card\"\u003e\n\u003cstrong\u003eRecurring Drain Freeze-Up\u003c\/strong\u003e\n\u003cdiv class=\"yd-mini-tags\"\u003e\n\u003cspan\u003eFrozen Drain Openings\u003c\/span\u003e \u003cspan\u003eFreeze-Thaw Cycles\u003c\/span\u003e \u003cspan\u003eRecurring Ice\u003c\/span\u003e \u003cspan\u003eWinter Drainage\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"yd-category-card\"\u003e\n\u003cstrong\u003eMeltwater Ponding\u003c\/strong\u003e\n\u003cdiv class=\"yd-mini-tags\"\u003e\n\u003cspan\u003eWater Around Drain\u003c\/span\u003e \u003cspan\u003eLocalized Ponding\u003c\/span\u003e \u003cspan\u003eBlocked Drainage\u003c\/span\u003e \u003cspan\u003eIce Formation\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"yd-category-card\"\u003e\n\u003cstrong\u003eRetrofit Projects\u003c\/strong\u003e\n\u003cdiv class=\"yd-mini-tags\"\u003e\n\u003cspan\u003eExisting Roof Drains\u003c\/span\u003e \u003cspan\u003eCommercial Roofs\u003c\/span\u003e \u003cspan\u003eFacility Upgrades\u003c\/span\u003e \u003cspan\u003eWinterization\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"yd-category-card\"\u003e\n\u003cstrong\u003eRestricted Drain Locations\u003c\/strong\u003e\n\u003cdiv class=\"yd-mini-tags\"\u003e\n\u003cspan\u003eNear Parapets\u003c\/span\u003e \u003cspan\u003eNear Curbs\u003c\/span\u003e \u003cspan\u003eNear Walls\u003c\/span\u003e \u003cspan\u003eNear Equipment\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eWhen to Consider Roof Drain De-Icing\u003c\/h4\u003e\n\u003cdiv class=\"yd-check-grid\"\u003e\n\u003cspan\u003eIce repeatedly forms around an internal roof drain\u003c\/span\u003e \u003cspan\u003eMeltwater ponds near the drain during winter\u003c\/span\u003e \u003cspan\u003eThe drain throat or upper drainage path freezes\u003c\/span\u003e \u003cspan\u003eMaintenance teams repeatedly remove ice from the same drain\u003c\/span\u003e \u003cspan\u003eStandard roof-edge heating cable does not protect the internal drain\u003c\/span\u003e \u003cspan\u003eA repeatable drain-focused heating layout is required\u003c\/span\u003e\n\u003c\/div\u003e\n\u003ch4\u003eTypical Customers\u003c\/h4\u003e\n\u003cdiv class=\"yd-scenario-grid\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eFacility Managers\u003c\/strong\u003e \u003cspan\u003eFor properties with recurring winter drainage problems at specific internal roof drains.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eRoofing Contractors\u003c\/strong\u003e \u003cspan\u003eFor compatible retrofit projects where localized drain freeze protection is required.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eElectricians \u0026amp; Installers\u003c\/strong\u003e \u003cspan\u003eFor professionally planned roof de-icing systems requiring controlled cable placement.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eCommercial Property Owners\u003c\/strong\u003e \u003cspan\u003eFor offices, retail properties, warehouses, multifamily buildings, and institutional facilities.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eNot Intended For\u003c\/h4\u003e\n\u003cdiv class=\"yd-alert-box\"\u003e\n\u003cul\u003e\n\u003cli\u003eMelting snow across an entire roof surface\u003c\/li\u003e\n\u003cli\u003eStandard sloped-roof eave and gutter de-icing layouts\u003c\/li\u003e\n\u003cli\u003eEmergency removal of large existing ice accumulations\u003c\/li\u003e\n\u003cli\u003eReplacing proper roof slope or drainage design\u003c\/li\u003e\n\u003cli\u003eReplacing drain cleaning, roof inspection, or snow-load management\u003c\/li\u003e\n\u003cli\u003eRepairing damaged roof drains, blocked drainpipes, or failed roofing membranes\u003c\/li\u003e\n\u003cli\u003eHazardous locations unless the exact system and installation are approved for that application\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003eFor conventional roof edges, gutters, valleys, and downspouts, browse the \u003ca href=\"https:\/\/yelodeer.com\/collections\/roof-de-icing\"\u003e\u003cstrong\u003eYeloDeer Roof De-Icing Collection\u003c\/strong\u003e\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv class=\"yd-product-section\"\u003e\n\u003ch4\u003eProduct Specifications\u003c\/h4\u003e\n\u003ctable class=\"yd-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eFlat roof drain de-icing and freeze-protection system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eFRDDS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComplete Kit Model\u003c\/td\u003e\n\u003ctd\u003eFRDDS-50P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Application\u003c\/td\u003e\n\u003ctd\u003eInternal drain freeze protection on flat and low-slope roofs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Technology\u003c\/td\u003e\n\u003ctd\u003eSelf-regulating heating cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Cable Certification\u003c\/td\u003e\n\u003ctd\u003eCSA certified heating cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Voltage\u003c\/td\u003e\n\u003ctd\u003e120V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Output\u003c\/td\u003e\n\u003ctd\u003e5 W\/ft at 50°F \/ 10°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Cable Length\u003c\/td\u003e\n\u003ctd\u003e50 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Cord Length\u003c\/td\u003e\n\u003ctd\u003e25 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Connection\u003c\/td\u003e\n\u003ctd\u003ePlug-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAluminum Assembly\u003c\/td\u003e\n\u003ctd\u003eCenter aluminum ring with 6 grooved aluminum panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Drain Size\u003c\/td\u003e\n\u003ctd\u003eUp to 14 in \/ 355 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Compatible Cable Profile\u003c\/td\u003e\n\u003ctd\u003e6 mm × 13 mm \/ approx. 0.24 in × 0.51 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel Length\u003c\/td\u003e\n\u003ctd\u003e24 in \/ 600 mm each\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eSelf-regulating cable; compatible automatic roof de-icing controller recommended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround-Fault Protection\u003c\/td\u003e\n\u003ctd\u003eRequired GFCI\/GFEP protection must be provided\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Type\u003c\/td\u003e\n\u003ctd\u003eRooftop drain-area installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv class=\"yd-alert-box\"\u003e\n\u003cp\u003e\u003cstrong\u003eCertification note:\u003c\/strong\u003e the supplied product information confirms CSA certification for the heating cable included with the Complete Kit. This should not be interpreted as certification of every custom system, third-party component, or site-specific installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch4\u003eCustom Project Options\u003c\/h4\u003e\n\u003cdiv class=\"yd-scenario-grid\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eCustom Cable Lengths\u003c\/strong\u003e \u003cspan\u003eProject-specific lengths may be available when the standard 50 ft cable does not match the required layout.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e240V Systems\u003c\/strong\u003e \u003cspan\u003eContact YeloDeer for projects requiring 240V rather than the standard 120V Complete Kit.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eHardwired Installation\u003c\/strong\u003e \u003cspan\u003eCustom professional installations can be reviewed for hardwired power and connection requirements.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eMultiple Roof Drains\u003c\/strong\u003e \u003cspan\u003eCommercial projects with multiple drains can be reviewed for cable, control, accessory, and quantity requirements.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eFor custom configurations, visit \u003ca href=\"https:\/\/yelodeer.com\/pages\/project-consultation-for-freeze-protection-solutions\"\u003e\u003cstrong\u003eYeloDeer Project Consultation\u003c\/strong\u003e\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eFor field-terminated cable systems, also review the \u003ca href=\"https:\/\/yelodeer.com\/products\/yelodeer-heat-trace-cable-connection-termination-kits\"\u003e\u003cstrong\u003eHeat Trace Cable Connection \u0026amp; Termination Kits\u003c\/strong\u003e\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eInstallation\u003c\/h3\u003e\n\u003cdiv class=\"yd-product-section\"\u003e\n\u003ch4\u003eInstallation Overview\u003c\/h4\u003e\n\u003cp\u003eThe system is installed around a compatible internal roof drain. The aluminum assembly positions the heating cable around the drain opening, while a suitable portion of cable can extend into the drainage path to help protect the freeze-prone section below the roof surface.\u003c\/p\u003e\n\u003cp\u003eReview the applicable product instructions before installation. Rooftop and electrical work should be performed by qualified personnel where required.\u003c\/p\u003e\n\u003ch4\u003eBasic Installation Steps\u003c\/h4\u003e\n\u003cdiv class=\"yd-install-grid\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e1. Prepare the Drain Area\u003c\/strong\u003e \u003cspan\u003eRemove leaves, gravel, ice, and debris. Confirm the drain, roof surface, and surrounding area are suitable for installation.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e2. Position the Center Ring\u003c\/strong\u003e \u003cspan\u003ePlace the center aluminum spacer ring around the compatible roof drain dome or strainer and center the assembly around the drain opening.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e3. Install the Aluminum Panels\u003c\/strong\u003e \u003cspan\u003eAttach the grooved aluminum panels to the center ring. Use all six when space permits, or omit panels where a wall, curb, parapet, or other obstruction requires a modified layout.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e4. Install the Heating Cable\u003c\/strong\u003e \u003cspan\u003ePlan the cable path before inserting it into the grooves. Insert the flat cable and rotate it 90° so the narrow side sits vertically and securely in the groove.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e5. Extend Cable into the Drain\u003c\/strong\u003e \u003cspan\u003eRoute a suitable length into the drain toward the freeze-prone area without blocking the drainage opening or interfering with the dome or strainer.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e6. Connect Protected Power\u003c\/strong\u003e \u003cspan\u003eConnect the system to a properly grounded 120V source with the required GFCI\/GFEP protection. Verify the system before normal winter operation.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eImportant Installation Notes\u003c\/h4\u003e\n\u003cdiv class=\"yd-alert-box\"\u003e\n\u003cul\u003e\n\u003cli\u003ePlan the full cable route before pressing the cable into the aluminum grooves.\u003c\/li\u003e\n\u003cli\u003eDo not drag the cable jacket against aluminum edges when repositioning it.\u003c\/li\u003e\n\u003cli\u003eDo not crush, kink, puncture, sharply bend, or otherwise damage the heating cable.\u003c\/li\u003e\n\u003cli\u003eKeep the roof drain opening and water-flow path clear at all times.\u003c\/li\u003e\n\u003cli\u003eDo not allow cable placement to interfere with the drain dome or strainer.\u003c\/li\u003e\n\u003cli\u003eA roof de-icing controller does not replace required GFCI\/GFEP electrical protection.\u003c\/li\u003e\n\u003cli\u003eHardwired, 240V, field-terminated, and other custom systems should be handled by qualified professionals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch4\u003eCable Placement Inside the Drain\u003c\/h4\u003e\n\u003cp\u003eThere is no single insertion depth suitable for every roof drain. The required cable depth depends on the drain construction, location of the freeze-prone area, available cable length, and site conditions.\u003c\/p\u003e\n\u003cp\u003eUse enough cable to provide targeted protection where freezing occurs while keeping the drainage path open.\u003c\/p\u003e\n\u003ch4\u003eRecommended Automatic Control\u003c\/h4\u003e\n\u003cp\u003eSelf-regulating heating cable changes heat output as local temperature changes, but it does not completely switch itself off. For more automatic and energy-conscious winter operation, consider the \u003ca href=\"https:\/\/yelodeer.com\/products\/roof-heating-control\"\u003e\u003cstrong\u003eYeloDeer Smart Roof De-Icing Controller\u003c\/strong\u003e\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eBefore adding a controller, confirm voltage, total connected load, electrical protection, sensor placement, and compatibility with the final roof de-icing configuration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cdiv class=\"yd-product-section yd-faq-section\"\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow is this different from a standard roof and gutter heating cable?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eStandard roof de-icing cable is normally routed along roof edges, eaves, valleys, gutters, and downspouts to maintain perimeter drainage paths.\u003c\/p\u003e\n\u003cp\u003eThis system is specifically designed around an internal drain on a flat or low-slope roof. The aluminum panels organize heating cable around the drain, while part of the cable can extend into the drainage path below the roof surface.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan I use this system on a sloped roof?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eThis system is intended primarily for flat and low-slope roofs that rely on internal roof drains.\u003c\/p\u003e\n\u003cp\u003eFor conventional sloped-roof edges, gutters, valleys, and downspouts, choose a standard solution from the \u003ca href=\"https:\/\/yelodeer.com\/collections\/roof-de-icing\"\u003e\u003cstrong\u003eYeloDeer Roof De-Icing Collection\u003c\/strong\u003e\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWill this system melt all the snow on my roof?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eNo. It is not a whole-roof snow-melting system.\u003c\/p\u003e\n\u003cp\u003eIts purpose is to concentrate heat around the drain and help maintain a path for meltwater to reach and enter the drainage system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat roof drain size is compatible?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe center assembly is designed for compatible roof drains up to 14 in \/ 355 mm.\u003c\/p\u003e\n\u003cp\u003eBefore ordering, also confirm the available space around the drain, dome or strainer configuration, roof surface condition, and planned cable route.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow far should the heating cable extend into the drain?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eThere is no universal insertion depth. The required depth depends on where the drain freezes, the drain configuration, available cable length, and site conditions.\u003c\/p\u003e\n\u003cp\u003eRoute enough cable toward the freeze-prone section while making sure it does not restrict water flow or interfere with the drain dome or strainer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eDo I have to install all six aluminum panels?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eNot necessarily. All six panels can be used when the drain is located in an open roof area.\u003c\/p\u003e\n\u003cp\u003eIf a drain is close to a parapet, wall, curb, or rooftop equipment, one or more panels may be omitted as long as the remaining assembly is stable and does not interfere with drainage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eDoes the system need a controller or GFCI\/GFEP protection?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eRequired GFCI\/GFEP electrical protection must be provided for the heating cable circuit.\u003c\/p\u003e\n\u003cp\u003eA controller is recommended for automatic and more energy-conscious operation, but it does not replace required ground-fault protection. For compatible 120V projects, review the \u003ca href=\"https:\/\/yelodeer.com\/products\/roof-heating-control\"\u003e\u003cstrong\u003eYeloDeer Smart Roof De-Icing Controller\u003c\/strong\u003e\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan I order a different cable length, 240V version, or custom commercial system?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eYes. Contact YeloDeer before ordering if the standard 50 ft, 120V Complete Kit does not match your project.\u003c\/p\u003e\n\u003cp\u003eProject options may include custom cable lengths, 240V configurations, hardwired installations, aluminum assemblies without the standard cable, multiple-drain layouts, and bulk cable supply.\u003c\/p\u003e\n\u003cp\u003eFor custom layouts, visit \u003ca href=\"https:\/\/yelodeer.com\/pages\/project-consultation-for-freeze-protection-solutions\"\u003e\u003cstrong\u003eYeloDeer Project Consultation\u003c\/strong\u003e\u003c\/a\u003e or review the \u003ca href=\"https:\/\/yelodeer.com\/products\/yelodeer-cut-to-length-roof-deicing-cable\"\u003e\u003cstrong\u003eBulk Cut-to-Length Self-Regulating Heat Trace Cable\u003c\/strong\u003e\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003ch3\u003eGuides\u003c\/h3\u003e\n\u003cdiv class=\"yd-product-section\"\u003e\n\u003ch4\u003ePre-Installation Checklist\u003c\/h4\u003e\n\u003cdiv class=\"yd-check-grid\"\u003e\n\u003cspan\u003eConfirm the roof is flat or low-slope\u003c\/span\u003e \u003cspan\u003eConfirm the roof uses an internal drain\u003c\/span\u003e \u003cspan\u003eMeasure the drain opening and surrounding area\u003c\/span\u003e \u003cspan\u003eIdentify the section that repeatedly freezes\u003c\/span\u003e \u003cspan\u003ePlan the complete 50 ft cable route\u003c\/span\u003e \u003cspan\u003eConfirm suitable 120V power\u003c\/span\u003e \u003cspan\u003eConfirm required GFCI\/GFEP protection\u003c\/span\u003e \u003cspan\u003eCheck that cable placement will not block drainage\u003c\/span\u003e \u003cspan\u003eInspect the roof membrane and drain area\u003c\/span\u003e \u003cspan\u003eDetermine whether automatic control is required\u003c\/span\u003e\n\u003c\/div\u003e\n\u003ch4\u003eWinter Use \u0026amp; Inspection Guide\u003c\/h4\u003e\n\u003cdiv class=\"yd-install-grid\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eInspect Before Winter\u003c\/strong\u003e \u003cspan\u003eCheck the drain area, aluminum assembly, heating cable, power cord, and electrical connection before freezing weather begins.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eKeep the Drain Clear\u003c\/strong\u003e \u003cspan\u003eRemove leaves, gravel, debris, and other material that could restrict drainage around the drain opening.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eCheck Cable Position\u003c\/strong\u003e \u003cspan\u003eConfirm the heating cable remains properly seated and has not been crushed, cut, pulled, or displaced.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eCheck the Drain Path\u003c\/strong\u003e \u003cspan\u003eMake sure cable extending into the drain remains positioned without restricting normal water flow.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eInspect After Roof Work\u003c\/strong\u003e \u003cspan\u003eRecheck the system after roofing repairs, drain maintenance, equipment installation, or other rooftop work.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eDisconnect Damaged Systems\u003c\/strong\u003e \u003cspan\u003eDo not operate the system if the cable, power connection, or other electrical components appear damaged.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eChoosing the Right System\u003c\/h4\u003e\n\u003cdiv class=\"yd-scenario-grid\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eStandard 120V Project\u003c\/strong\u003e \u003cspan\u003eChoose the Complete Kit when a 50 ft plug-in heating cable and the standard aluminum drain assembly match the installation.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eCustom Cable Length\u003c\/strong\u003e \u003cspan\u003eFor project-specific lengths or multiple circuits, review the YeloDeer bulk cut-to-length cable platform.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eAutomatic Operation\u003c\/strong\u003e \u003cspan\u003eAdd a compatible roof de-icing controller when automatic temperature and moisture-based operation is preferred.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eCommercial or 240V Project\u003c\/strong\u003e \u003cspan\u003eUse YeloDeer Project Consultation for 240V, hardwired, multiple-drain, bulk, or site-specific configurations.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eRelated YeloDeer Resources\u003c\/h4\u003e\n\u003cdiv class=\"yd-category-grid\"\u003e\n\u003cdiv class=\"yd-category-card\"\u003e\n\u003cstrong\u003eBulk Roof De-Icing Cable\u003c\/strong\u003e\n\u003cp\u003eFor professional projects requiring custom cable lengths, field termination, multiple circuits, or 120V \/ 240V configurations.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/yelodeer.com\/products\/yelodeer-cut-to-length-roof-deicing-cable\"\u003e\u003cstrong\u003eView Bulk Heat Trace Cable →\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"yd-category-card\"\u003e\n\u003cstrong\u003eRoof De-Icing Controller\u003c\/strong\u003e\n\u003cp\u003eAutomatic temperature and moisture-based control for compatible 120V roof de-icing systems.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/yelodeer.com\/products\/roof-heating-control\"\u003e\u003cstrong\u003eView Roof De-Icing Controller →\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"yd-category-card\"\u003e\n\u003cstrong\u003eConnection \u0026amp; Termination Kits\u003c\/strong\u003e\n\u003cp\u003ePower connections, end seals, splice kits, and tee kits for compatible professional cut-to-length cable installations.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/yelodeer.com\/products\/yelodeer-heat-trace-cable-connection-termination-kits\"\u003e\u003cstrong\u003eView Connection Kits →\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"yd-category-card\"\u003e\n\u003cstrong\u003eRoof De-Icing Solutions\u003c\/strong\u003e\n\u003cp\u003eCompare roof heating cables, controllers, mounting accessories, and other winter drainage solutions.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/yelodeer.com\/collections\/roof-de-icing\"\u003e\u003cstrong\u003eExplore Roof De-Icing Solutions →\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003ePlanning \u0026amp; Technical Support\u003c\/h4\u003e\n\u003cp\u003eFor additional roof drainage and freeze-protection information, visit the \u003ca href=\"https:\/\/yelodeer.com\/pages\/knowledge-center\"\u003e\u003cstrong\u003eYeloDeer Knowledge Center\u003c\/strong\u003e\u003c\/a\u003e and \u003ca href=\"https:\/\/yelodeer.com\/pages\/installation-guide\"\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eFor commercial flat roofs, multiple drains, custom cable lengths, 240V systems, hardwired installations, or uncertain layouts, use the \u003ca href=\"https:\/\/yelodeer.com\/pages\/project-consultation-for-freeze-protection-solutions\"\u003e\u003cstrong\u003eProject Consultation\u003c\/strong\u003e\u003c\/a\u003e page.\u003c\/p\u003e\n\u003cp\u003eIf you need help with product selection or installation questions, \u003ca href=\"https:\/\/yelodeer.com\/pages\/contact\"\u003e\u003cstrong\u003econtact YeloDeer Product Support\u003c\/strong\u003e\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"YeloDeer","offers":[{"title":"Complete Kit – 50 ft 120V Cable","offer_id":48669418193137,"sku":"Complete Kit","price":568.99,"currency_code":"USD","in_stock":false},{"title":"Aluminum Assembly Only","offer_id":48669418225905,"sku":"Aluminum Assembly Only","price":378.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0701\/2836\/9905\/files\/FlatRoofDrainDe-IcingKit.png?v=1788240866","url":"https:\/\/yelodeer.com\/products\/flat-roof-drain-deicing-system","provider":"YeloDeer","version":"1.0","type":"link"}