{"product_id":"ceg-pipe-tank-in-pipe-heating-kit","title":"Pipe \u0026 Tank In-Pipe Freeze Protection Kit with Cable Entry Gland (CEG)","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cdiv class=\"yd-product-section\"\u003e\n\u003cp\u003e\u003cstrong\u003eCreate a sealed heating-cable entry closer to the area that freezes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis kit combines a \u003cstrong\u003eCSA-certified self-regulating in-pipe heating cable\u003c\/strong\u003e with a \u003cstrong\u003eCable Entry Gland\u003c\/strong\u003e. It creates a sealed cable-entry point through a compatible pipe wall, cleanout cap, tank wall, or flat surface so the heating cable can be routed inside.\u003c\/p\u003e\n\n\u003cdiv class=\"yd-decision-strip\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eLow-Static-Head Use\u003c\/strong\u003e\n\u003cspan\u003eFor compatible low-static-head pipes, tanks, drains, and containment applications.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eRound Pipe Entry\u003c\/strong\u003e\n\u003cspan\u003eDirect pipe-wall entry requires a round pipe at least 2 in in diameter and a compatible curved washer fit.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e3 Entry Options\u003c\/strong\u003e\n\u003cspan\u003eRound pipe wall, cleanout cap, or tank and flat-surface entry.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eCSA-Certified Cable\u003c\/strong\u003e\n\u003cspan\u003eCompatible self-regulating in-pipe heating cable is included.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eBefore Ordering\u003c\/h4\u003e\n\u003cdiv class=\"yd-check-grid\"\u003e\n\u003cspan\u003eYour application is low-static-head\u003c\/span\u003e\n\u003cspan\u003eThe mounting surface is smooth, rigid, and structurally sound\u003c\/span\u003e\n\u003cspan\u003eWall thickness is approx. 1\/8–1 in \/ 3–25.4 mm\u003c\/span\u003e\n\u003cspan\u003eThere is enough internal clearance for the retaining plate\u003c\/span\u003e\n\u003cspan\u003eThe heating cable can reach the freeze-prone section\u003c\/span\u003e\n\u003cspan\u003eThe supplied washer matches the planned mounting surface\u003c\/span\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"yd-notice-box\"\u003e\n\u003cp\u003e\u003cstrong\u003eRound pipe fit:\u003c\/strong\u003e The supplied curved washers are identified for 2 in and 3–4 in round pipe applications. The pipe-wall entry requires at least a 2 in round pipe. Confirm washer fit before drilling.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eWhat’s Included\u003c\/h4\u003e\n\u003cdiv class=\"yd-do-dont-grid\"\u003e\n\u003cdiv class=\"yd-do-card\"\u003e\n\u003cstrong\u003eIncluded\u003c\/strong\u003e\n\u003cspan\u003eSelected in-pipe heating cable, complete Cable Entry Gland assembly, curved and flat washers, 25 mm \/ approx. 1 in hole saw, temporary closure plug, installation manual, and spare mounting parts.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"yd-dont-card\"\u003e\n\u003cstrong\u003eSold Separately\u003c\/strong\u003e\n\u003cspan\u003ePipe or tank insulation and an external thermostat or temperature controller are not included.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"yd-alert-box\"\u003e\n\u003cp\u003e\u003cstrong\u003eNot for pressurized plumbing.\u003c\/strong\u003e Do not install the Cable Entry Gland on municipal water pressure lines, pressurized household plumbing, pressure vessels, gas piping, fuel tanks, or high-pressure equipment.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"yd-notice-box\"\u003e\n\u003cp\u003e\u003cstrong\u003eSump pump discharge lines:\u003c\/strong\u003e This kit can be used where the installation remains within the product's low-static-head application limits. Do not treat the Cable Entry Gland as a pressure-rated plumbing fitting.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"yd-alert-box\"\u003e\n\u003cp\u003e\u003cstrong\u003eSelf-regulating does not mean automatic shutoff.\u003c\/strong\u003e Heat output changes with temperature, but the cable remains energized while connected to power. Add a compatible external thermostat when automatic temperature-based on\/off control is needed.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eChoose a Different Solution If Needed\u003c\/h4\u003e\n\u003cp\u003eFor a \u003cstrong\u003epressurized potable-water supply line\u003c\/strong\u003e, use the \u003ca href=\"https:\/\/yelodeer.com\/products\/yelodeer-y-in-pipe-heating-cable\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eYeloDeer Y-Fitting In-Pipe Heating Cable →\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\n\u003cp\u003eFor a \u003cstrong\u003e1\/2 in or 3\/4 in non-pressurized condensate or small drain line\u003c\/strong\u003e, see the \u003ca href=\"https:\/\/yelodeer.com\/products\/drainguard-condensate-drain-heating-cable-kit\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eYeloDeer DrainGuard Heating Cable Kit →\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv class=\"yd-product-section\"\u003e\n\u003ch4\u003eThree Cable-Entry Options\u003c\/h4\u003e\n\n\u003cdiv class=\"yd-category-grid\"\u003e\n\u003cdiv class=\"yd-category-card\"\u003e\n\u003cstrong\u003eRound Pipe Wall\u003c\/strong\u003e\n\u003cdiv class=\"yd-mini-tags\"\u003e\n\u003cspan\u003eDrain Pipe\u003c\/span\u003e\n\u003cspan\u003eWastewater\u003c\/span\u003e\n\u003cspan\u003eSump Discharge\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cp\u003eCreate an entry directly through a suitable round pipe wall when the freeze-prone section is not near an existing access point.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"yd-category-card\"\u003e\n\u003cstrong\u003eCleanout Cap\u003c\/strong\u003e\n\u003cdiv class=\"yd-mini-tags\"\u003e\n\u003cspan\u003eCleanout Caps\u003c\/span\u003e\n\u003cspan\u003eService Covers\u003c\/span\u003e\n\u003cspan\u003eInspection Ports\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cp\u003eInstall through a smooth, rigid flat area with enough internal clearance for the retaining plate.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"yd-category-card\"\u003e\n\u003cstrong\u003eTank \u0026amp; Flat Surface\u003c\/strong\u003e\n\u003cdiv class=\"yd-mini-tags\"\u003e\n\u003cspan\u003eWater Tanks\u003c\/span\u003e\n\u003cspan\u003eRV Holding Tanks\u003c\/span\u003e\n\u003cspan\u003eFlat Panels\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cp\u003eCreate an internal heating-cable entry through a compatible rigid tank wall or flat containment surface.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eSuitable Low-Static-Head Applications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDrain pipes\u003c\/li\u003e\n\u003cli\u003eSewer pipes\u003c\/li\u003e\n\u003cli\u003eWastewater pipes\u003c\/li\u003e\n\u003cli\u003eSump pump discharge lines within the low-static-head application limits\u003c\/li\u003e\n\u003cli\u003eNon-pressurized plumbing vent pipes and vent stacks\u003c\/li\u003e\n\u003cli\u003eCleanout caps and compatible service covers\u003c\/li\u003e\n\u003cli\u003ePotable and non-potable water storage tanks when all applicable wetted materials are suitable\u003c\/li\u003e\n\u003cli\u003eRV holding tanks\u003c\/li\u003e\n\u003cli\u003eInspection ports\u003c\/li\u003e\n\u003cli\u003eCompatible metal, plastic, fiberglass, and other rigid containment surfaces\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eMounting Surface Requirements\u003c\/h4\u003e\n\u003cdiv class=\"yd-do-dont-grid\"\u003e\n\u003cdiv class=\"yd-do-card\"\u003e\n\u003cstrong\u003eUse on\u003c\/strong\u003e\n\u003cspan\u003eSmooth, rigid, structurally sound surfaces capable of supporting gasket compression. Compatible materials may include PVC, ABS, PE, PP, fiberglass, metal, and similar rigid materials.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"yd-dont-card\"\u003e\n\u003cstrong\u003eAvoid\u003c\/strong\u003e\n\u003cspan\u003eCracks, deep scratches, heavy texture, corrugations, flexible walls, sharp curves, seams, molded ribs, raised lettering, threaded areas, or locations too close to an edge.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"yd-alert-box\"\u003e\n\u003cp\u003e\u003cstrong\u003eDo not use on pressurized systems.\u003c\/strong\u003e This includes municipal water pressure lines, pressurized household plumbing, pressure vessels, gas systems, fuel systems, and high-pressure equipment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv class=\"yd-product-section\"\u003e\n\u003ch4\u003eProduct Specifications\u003c\/h4\u003e\n\u003ctable class=\"yd-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePipe and tank in-pipe freeze protection kit with Cable Entry Gland\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Cable Type\u003c\/td\u003e\n\u003ctd\u003eSelf-regulating in-pipe heating cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Cable Certification\u003c\/td\u003e\n\u003ctd\u003eCSA certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Type\u003c\/td\u003e\n\u003ctd\u003eLow-static-head pipe, tank, drain, and containment applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEntry Methods\u003c\/td\u003e\n\u003ctd\u003eRound pipe wall, cleanout cap, tank wall, flat panel, and compatible containment surface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRound Pipe Wall Entry\u003c\/td\u003e\n\u003ctd\u003eMinimum 2 in round pipe; supplied curved washers are identified for 2 in and 3–4 in pipe applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Entry Hole\u003c\/td\u003e\n\u003ctd\u003e25 mm \/ approx. 1 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHole Saw\u003c\/td\u003e\n\u003ctd\u003e25 mm \/ approx. 1 in hole saw included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Mounting Wall Thickness\u003c\/td\u003e\n\u003ctd\u003eApprox. 1\/8 in to 1 in \/ 3 mm to 25.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Compatibility\u003c\/td\u003e\n\u003ctd\u003eDesigned for the specified heating cable profile, approx. 0.42 × 0.20 in \/ 10.7 × 5.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeal Type\u003c\/td\u003e\n\u003ctd\u003eMechanical compression seal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Mounting Materials\u003c\/td\u003e\n\u003ctd\u003ePVC, ABS, PE, PP, fiberglass, metal, and similar smooth, rigid materials\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Surface Requirement\u003c\/td\u003e\n\u003ctd\u003eSmooth, rigid, structurally sound, and capable of supporting gasket compression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Limit\u003c\/td\u003e\n\u003ctd\u003eLow-static-head applications only; not for pressurized plumbing systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemporary Hole Closure\u003c\/td\u003e\n\u003ctd\u003eRubber Closure Plug included for temporary closure after the cable-entry assembly and heating cable are removed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpare Parts\u003c\/td\u003e\n\u003ctd\u003e2 spare Screws (D) and 1 spare Crescent Retaining Plate (E)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch4\u003eIncluded Cable-Entry Components\u003c\/h4\u003e\n\u003ctable class=\"yd-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003eFlange Base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eCurved Rubber Washers for compatible round pipe surfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB'\u003c\/td\u003e\n\u003ctd\u003eFlat Rubber Washer for tank walls, cleanout caps, and flat surfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eFlange Sealing Gasket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003ctd\u003eMounting Screws ×2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE\u003c\/td\u003e\n\u003ctd\u003eCrescent Retaining Plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003ctd\u003eFlange Cable Outlet Fitting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG\u003c\/td\u003e\n\u003ctd\u003eCompression Nut\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH\u003c\/td\u003e\n\u003ctd\u003eFitting Gasket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\u003c\/td\u003e\n\u003ctd\u003eSilicone Sealing Plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJ\u003c\/td\u003e\n\u003ctd\u003e25 mm \/ approx. 1 in Hole Saw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK\u003c\/td\u003e\n\u003ctd\u003eRubber Closure Plug for temporary hole closure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cdiv class=\"yd-notice-box\"\u003e\n\u003cp\u003e\u003cstrong\u003eCable size and profile matter.\u003c\/strong\u003e The sealing components are designed around the specified heating cable. Do not substitute another cable size or shape unless compatibility has been confirmed by YeloDeer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eInstallation\u003c\/h3\u003e\n\u003cdiv class=\"yd-product-section\"\u003e\n\u003ch4\u003eBefore Installation\u003c\/h4\u003e\n\u003cdiv class=\"yd-check-grid\"\u003e\n\u003cspan\u003eConfirm low-static-head application\u003c\/span\u003e\n\u003cspan\u003eConfirm mounting wall thickness\u003c\/span\u003e\n\u003cspan\u003eConfirm washer and surface fit\u003c\/span\u003e\n\u003cspan\u003eCheck internal retaining-plate clearance\u003c\/span\u003e\n\u003cspan\u003eMeasure the required cable route\u003c\/span\u003e\n\u003cspan\u003eInspect the heating cable jacket\u003c\/span\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eBasic Installation Sequence\u003c\/h4\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eChoose the entry location.\u003c\/strong\u003e Select a smooth, rigid area with enough sealing surface around the hole.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrill the entry hole.\u003c\/strong\u003e Use the included 25 mm \/ approx. 1 in Hole Saw (J). Keep the drill as perpendicular to the surface as possible.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDeburr the hole.\u003c\/strong\u003e Remove sharp edges, plastic debris, and metal shavings from both sides.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelect the washer.\u003c\/strong\u003e Use Curved Rubber Washer (B) for a compatible round pipe. Use Flat Rubber Washer (B') for cleanout caps, tank walls, and flat surfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsert the A-D-E Assembly.\u003c\/strong\u003e Insert the pre-assembled flange base, screw, and retaining plate through the entry hole.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecure the retaining plate.\u003c\/strong\u003e Use two screwdrivers. One stabilizes the Crescent Retaining Plate (E) while the other tightens the mounting screw. Install the second screw and alternately tighten both.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall the outlet fitting.\u003c\/strong\u003e Seat Flange Sealing Gasket (C), then install Flange Cable Outlet Fitting (F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrepare the cable.\u003c\/strong\u003e Slide Compression Nut (G) and Fitting Gasket (H) onto the cable before routing it through the entry assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoute the heating cable.\u003c\/strong\u003e Feed it slowly toward the intended freeze-prone section.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete the cable seal.\u003c\/strong\u003e Install Silicone Sealing Plug (I), position H, and hand-tighten G until properly seated.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeak-check before power.\u003c\/strong\u003e Inspect the mounting flange and cable entry for moisture or leakage before energizing the heating cable.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003cdiv class=\"yd-alert-box\"\u003e\n\u003cp\u003e\u003cstrong\u003eNever completely remove both mounting screws at the same time.\u003c\/strong\u003e Keep at least one screw partially engaged with the Crescent Retaining Plate (E) so the plate cannot fall inside the pipe, tank, or containment structure.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch4\u003eLong Pipe Runs\u003c\/h4\u003e\n\u003cdiv class=\"yd-do-dont-grid\"\u003e\n\u003cdiv class=\"yd-do-card\"\u003e\n\u003cstrong\u003eUse a Pulling Line When Needed\u003c\/strong\u003e\n\u003cspan\u003eIf the cable cannot be positioned by hand, feed fish tape or a strong pulling line from the far end toward the cable-entry location. Attach it to the heating cable and pull slowly while guiding the cable.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"yd-dont-card\"\u003e\n\u003cstrong\u003eDo Not Damage the Cable\u003c\/strong\u003e\n\u003cspan\u003eDo not use sharp wire, sharp hooks, or tools that can cut, scrape, puncture, crush, or heavily kink the heating cable jacket. Do not force the cable through resistance.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"yd-notice-box\"\u003e\n\u003cp\u003e\u003cstrong\u003eFinal check:\u003c\/strong\u003e Keep all gaskets correctly seated and do not overtighten plastic components. Check the completed installation for leakage before connecting power.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cdiv class=\"yd-product-section yd-faq-section\"\u003e\n\u003ch4\u003eFrequently Asked Questions\u003c\/h4\u003e\n\n\u003cdetails\u003e\n\u003csummary\u003eCan I use this kit on a sump pump discharge line?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eYes, when the selected installation remains within the product's low-static-head application limits. The Cable Entry Gland can create a cable-entry point closer to the freeze-prone section of the discharge line. It is not a pressure-rated plumbing fitting.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails\u003e\n\u003csummary\u003eCan I install it directly through a round pipe wall?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eYes. Direct pipe-wall entry requires a round pipe at least 2 in in diameter. The supplied curved washers are identified for 2 in and 3–4 in round pipe applications. Confirm washer fit, wall thickness, surface condition, and internal clearance before drilling.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails\u003e\n\u003csummary\u003eCan I install it through a cleanout cap or tank wall?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eYes. Use the Flat Rubber Washer on a suitable cleanout cap, tank wall, inspection port, or other smooth flat surface. The mounting area must be rigid, structurally sound, and capable of supporting gasket compression.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails\u003e\n\u003csummary\u003eCan this kit be used on a pressurized household water line?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eNo. The Cable Entry Gland is intended for low-static-head applications only. Do not use it on municipal water pressure lines, pressurized household plumbing, pressure vessels, gas piping, fuel tanks, or high-pressure equipment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails\u003e\n\u003csummary\u003eIs the included heating cable CSA certified?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eYes. The self-regulating in-pipe heating cable supplied with this kit is CSA certified.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails\u003e\n\u003csummary\u003eIs the hole saw included?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eYes. A 25 mm \/ approx. 1 in Hole Saw (J) is included for creating the required cable-entry hole. Do not enlarge, reshape, or modify the finished hole.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails\u003e\n\u003csummary\u003eWhat happens if I remove the cable-entry assembly later?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe kit includes a Rubber Closure Plug (K) for temporarily closing the original cable-entry hole after the assembly and heating cable are removed. It is a temporary closure for compatible low-static-head applications, not a pressure-rated plumbing plug.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails\u003e\n\u003csummary\u003eCan I use another heating cable with the Cable Entry Gland?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe sealing system is designed around the specified heating cable size and profile. Do not use another cable size or shape unless compatibility has been confirmed by YeloDeer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails\u003e\n\u003csummary\u003eDo I need insulation or a thermostat?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eNeither is included. Insulation is recommended where appropriate to reduce heat loss. A compatible thermostat or temperature controller can provide automatic temperature-based on\/off control when its voltage and electrical load requirements match the heating cable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eGuides\u003c\/h3\u003e\n\u003cdiv class=\"yd-product-section\"\u003e\n\u003cp\u003eUse the included installation manual for the complete Cable Entry Gland assembly procedure, component orientation, leak check, and safety instructions.\u003c\/p\u003e\n\n\u003cp\u003eNot sure whether an internal heating cable fits your application? Read \u003ca href=\"https:\/\/yelodeer.com\/blogs\/in-pipe-heating-cable\/can-heat-cable-go-inside-pipe\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eCan You Put Heat Cable Inside Any Pipe? →\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\n\u003cp\u003eProtecting a sump pump system? Read \u003ca href=\"https:\/\/yelodeer.com\/blogs\/knowledge-center\/sump-pump-frozen-discharge-line\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eHow to Prevent a Frozen Sump Pump Discharge Line →\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\n\u003cp\u003eFor automatic temperature-based power control, see the \u003ca href=\"https:\/\/yelodeer.com\/products\/pipe-heat-tape-thermostat\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eYeloDeer Pipe Heat Tape Thermostat Controller →\u003c\/strong\u003e\u003c\/a\u003e. Confirm voltage and connected load compatibility before use.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"YeloDeer","offers":[{"title":"Default Title","offer_id":48686333329649,"sku":null,"price":999.0,"currency_code":"USD","in_stock":false}],"url":"https:\/\/yelodeer.com\/products\/ceg-pipe-tank-in-pipe-heating-kit","provider":"YeloDeer","version":"1.0","type":"link"}