{"product_id":"beehive-heating-blanket","title":"Beehive Heating Blanket with Thermostat for 8 \u0026 10-Frame Hives","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cdiv class=\"yd-product-section\"\u003e\n\u003cp\u003e\u003cstrong\u003eBeehive Heating Blanket with Thermostat for 8 \u0026amp; 10-Frame Hives\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe YeloDeer beehive heating blanket combines an insulated winter hive wrap with a 350W low-intensity heating system and thermostat controller.\u003c\/p\u003e\n\u003cp\u003eIt can be used without power as a standard insulation wrap during mild or typical winter conditions, or connected to power to provide controlled supplemental heat during extreme cold.\u003c\/p\u003e\n\u003cdiv class=\"yd-alert-box\"\u003e\n\u003cp\u003e\u003cstrong\u003eImportant: This product is not a primary hive heating device.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is designed to reduce external heat loss and provide gentle supplemental heat only when necessary. It is not intended to make the hive warm, maintain room temperature, or replace the colony’s natural temperature regulation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch4\u003eQuick Fit Snapshot\u003c\/h4\u003e\n\u003cdiv class=\"yd-decision-strip\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e8 \u0026amp; 10-Frame Hives\u003c\/strong\u003e \u003cspan\u003e Adjustable wraparound design for compatible standard hive configurations. \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e350W Heating System\u003c\/strong\u003e \u003cspan\u003e Provides low-intensity supplemental surface heating during extreme cold. \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eThermostat Controlled\u003c\/strong\u003e \u003cspan\u003e External probe monitors hive-wall temperature and controls heater operation. \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eTwo Operating Modes\u003c\/strong\u003e \u003cspan\u003e Use without power for insulation or connect to power for supplemental heating. \u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eKey Benefits\u003c\/h4\u003e\n\u003cdiv class=\"yd-scenario-grid\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eInsulation and Heating in One\u003c\/strong\u003e \u003cspan\u003e Combines an external winter hive wrap with an integrated low-intensity heating system. \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eControlled Supplemental Heat\u003c\/strong\u003e \u003cspan\u003e The thermostat switches heating on and off based on the measured temperature and selected setting. \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eExternal Temperature Probe\u003c\/strong\u003e \u003cspan\u003e A separate probe pocket helps measure temperature at the hive wall rather than inside the heated blanket. \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eTool-Free Installation\u003c\/strong\u003e \u003cspan\u003e Velcro straps and buckle fasteners allow installation without permanent modification to the hive. \u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eTwo Ways to Use\u003c\/h4\u003e\n\u003cdiv class=\"yd-do-dont-grid\"\u003e\n\u003cdiv class=\"yd-do-card\"\u003e\n\u003cstrong\u003eInsulation Mode — No Power\u003c\/strong\u003e \u003cspan\u003e Use the blanket as a passive winter hive wrap during mild or typical winter conditions. No outlet or heating operation is required. \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"yd-do-card\"\u003e\n\u003cstrong\u003eHeating Mode — Powered\u003c\/strong\u003e \u003cspan\u003e Connect the blanket to the thermostat and a compatible 120V outlet when controlled supplemental heat is needed during extreme cold. \u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eSuitable For\u003c\/h4\u003e\n\u003cdiv class=\"yd-category-grid\"\u003e\n\u003cdiv class=\"yd-category-card\"\u003e\n\u003cstrong\u003eCompatible Hives\u003c\/strong\u003e\n\u003cdiv class=\"yd-mini-tags\"\u003e\n\u003cspan\u003e8-Frame Hives\u003c\/span\u003e \u003cspan\u003e10-Frame Hives\u003c\/span\u003e \u003cspan\u003eOutdoor Beehives\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"yd-category-card\"\u003e\n\u003cstrong\u003eCold-Weather Use\u003c\/strong\u003e\n\u003cdiv class=\"yd-mini-tags\"\u003e\n\u003cspan\u003eExtreme Cold Conditions\u003c\/span\u003e \u003cspan\u003eWinter Hive Protection\u003c\/span\u003e \u003cspan\u003eSupplemental Heating\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"yd-category-card\"\u003e\n\u003cstrong\u003eIncluded Functions\u003c\/strong\u003e\n\u003cdiv class=\"yd-mini-tags\"\u003e\n\u003cspan\u003e350W Heating\u003c\/span\u003e \u003cspan\u003eTemperature Control\u003c\/span\u003e \u003cspan\u003e°F \/ °C Display\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eOnly Need Passive Insulation?\u003c\/h4\u003e\n\u003cdiv class=\"yd-alert-box\"\u003e\n\u003cp\u003eIf your climate or hive-management plan does not require supplemental heating, choose the \u003ca href=\"\/products\/winter-beehive-insulation\"\u003e\u003cstrong\u003eWinter Beehive Insulation Wrap\u003c\/strong\u003e \u003c\/a\u003e\u003ca href=\"\/products\/winter-beehive-insulation\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eThe non-heated model provides similar external winter insulation without a heating element, thermostat, or electrical connection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch4\u003eImportant Before Ordering\u003c\/h4\u003e\n\u003cdiv class=\"yd-check-grid\"\u003e\n\u003cspan\u003e Confirm the hive fits the 77.6 × 24.8 in wrap dimensions \u003c\/span\u003e \u003cspan\u003e Confirm access to a properly installed 120V AC outlet \u003c\/span\u003e \u003cspan\u003e Use heating only when supplemental heat is genuinely necessary \u003c\/span\u003e \u003cspan\u003e Keep the hive entrance and ventilation openings unobstructed \u003c\/span\u003e \u003cspan\u003e Install the temperature probe correctly against the hive wall \u003c\/span\u003e \u003cspan\u003e Do not use the heater to create warm or room-temperature conditions \u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv class=\"yd-product-section\"\u003e\n\u003ch4\u003eRecommended Applications\u003c\/h4\u003e\n\u003cp\u003eThis heated beehive wrap is intended for compatible outdoor hives in cold climates where passive insulation may not be sufficient and carefully controlled supplemental heat is required.\u003c\/p\u003e\n\u003cdiv class=\"yd-category-grid\"\u003e\n\u003cdiv class=\"yd-category-card\"\u003e\n\u003cstrong\u003eExtreme Cold Support\u003c\/strong\u003e\n\u003cdiv class=\"yd-mini-tags\"\u003e\n\u003cspan\u003eSevere Winter Conditions\u003c\/span\u003e \u003cspan\u003eCold Exposure\u003c\/span\u003e \u003cspan\u003eSupplemental Hive Heat\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"yd-category-card\"\u003e\n\u003cstrong\u003eFlexible Seasonal Use\u003c\/strong\u003e\n\u003cdiv class=\"yd-mini-tags\"\u003e\n\u003cspan\u003eInsulation-Only Mode\u003c\/span\u003e \u003cspan\u003ePowered Heating Mode\u003c\/span\u003e \u003cspan\u003eSeasonal Installation\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"yd-category-card\"\u003e\n\u003cstrong\u003eControlled Heating\u003c\/strong\u003e\n\u003cdiv class=\"yd-mini-tags\"\u003e\n\u003cspan\u003eThermostat Operation\u003c\/span\u003e \u003cspan\u003eExternal Temperature Probe\u003c\/span\u003e \u003cspan\u003eAdjustable Temperature\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eWhen Heating May Be Appropriate\u003c\/h4\u003e\n\u003cdiv class=\"yd-do-dont-grid\"\u003e\n\u003cdiv class=\"yd-do-card\"\u003e\n\u003cstrong\u003eRecommended Use\u003c\/strong\u003e \u003cspan\u003e Use controlled supplemental heat only during extreme cold and only after considering the colony condition, local climate, hive ventilation, and normal winter-management practices. \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"yd-dont-card\"\u003e\n\u003cstrong\u003eDo Not Use To\u003c\/strong\u003e \u003cspan\u003e Create warm indoor-like conditions, eliminate natural winter temperature changes, replace food and moisture management, or continuously overheat the hive. \u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eWhich Beehive Wrap Should I Choose?\u003c\/h4\u003e\n\u003ctable class=\"yd-spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eInsulation Wrap\u003c\/th\u003e\n\u003cth\u003eHeating Blanket\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Insulation\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupplemental Heating\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003e350W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermostat Controller\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Required\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003e120V AC in heating mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Conditions\u003c\/td\u003e\n\u003ctd\u003eMild to typical winter conditions\u003c\/td\u003e\n\u003ctd\u003eExtreme cold when supplemental heat is necessary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Link\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/winter-beehive-insulation-wrap\"\u003e View Insulation Wrap \u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eCurrent Product\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eImportant Heating Principle\u003c\/h4\u003e\n\u003cdiv class=\"yd-alert-box\"\u003e\n\u003cp\u003eHoneybees normally generate their own heat and do not require the hive to reach warm indoor temperatures.\u003c\/p\u003e\n\u003cp\u003eBegin with a lower thermostat setting and increase only when necessary. Higher settings are usually unnecessary and may increase overheating risk.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv class=\"yd-product-section\"\u003e\n\u003ch4\u003eHeating Blanket Specifications\u003c\/h4\u003e\n\u003ctable class=\"yd-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInsulated beehive heating blanket system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e120V AC, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Power\u003c\/td\u003e\n\u003ctd\u003e350W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlanket Dimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 77.6 × 24.8 in (197 × 63 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Hive Sizes\u003c\/td\u003e\n\u003ctd\u003eStandard 8-frame and 10-frame hives\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFastening Type\u003c\/td\u003e\n\u003ctd\u003eVelcro straps and buckle fasteners\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Method\u003c\/td\u003e\n\u003ctd\u003eExternal wraparound installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Modes\u003c\/td\u003e\n\u003ctd\u003eInsulation-only mode and powered heating mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eThermostat Controller Specifications\u003c\/h4\u003e\n\u003ctable class=\"yd-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Voltage\u003c\/td\u003e\n\u003ctd\u003e120V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Controller Load\u003c\/td\u003e\n\u003ctd\u003e1200W \/ 10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Blanket Load\u003c\/td\u003e\n\u003ctd\u003e350W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Cable Length\u003c\/td\u003e\n\u003ctd\u003eApprox. 6.6 ft (2 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Cord Length\u003c\/td\u003e\n\u003ctd\u003eApprox. 3 ft (90 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Unit\u003c\/td\u003e\n\u003ctd\u003e°F \/ °C switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe\u003c\/td\u003e\n\u003ctd\u003eExternal probe installed in the included probe pocket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimer Function\u003c\/td\u003e\n\u003ctd\u003eAdjustable thermostat operating duration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e1-year limited warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eRecommended Temperature Guidance\u003c\/h4\u003e\n\u003ctable class=\"yd-spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSetting\u003c\/th\u003e\n\u003cth\u003eGuidance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuggested Starting Point\u003c\/td\u003e\n\u003ctd\u003e50–59°F (10–15°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefault Upper Limit\u003c\/td\u003e\n\u003ctd\u003eSet temperature +9°F (+5°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Allowed Set Temperature\u003c\/td\u003e\n\u003ctd\u003eDo not exceed 82°F (28°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Final Temperature\u003c\/td\u003e\n\u003ctd\u003eSet temperature plus upper limit must not exceed 91°F (33°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjustment Approach\u003c\/td\u003e\n\u003ctd\u003eBegin with a lower setting and increase only when necessary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv class=\"yd-alert-box\"\u003e\n\u003cp\u003e\u003cstrong\u003eThe recommended temperature values are safety limits, not instructions to maintain a warm hive.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eLocal weather, hive construction, colony condition, probe placement, and ventilation can affect actual temperature. Monitor the hive and adjust conservatively.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eInstallation\u003c\/h3\u003e\n\u003cdiv class=\"yd-product-section\"\u003e\n\u003ch4\u003eInstallation Overview\u003c\/h4\u003e\n\u003cp\u003eCorrect probe placement and unobstructed hive ventilation are essential. Complete the full installation before connecting the system to power.\u003c\/p\u003e\n\u003ch4\u003eInstallation Steps\u003c\/h4\u003e\n\u003col\u003e\n\u003cli\u003eInspect the heating blanket, thermostat, power cord, probe, probe pocket, straps, and buckle fasteners.\u003c\/li\u003e\n\u003cli\u003eInsert the temperature probe fully into the included probe pocket.\u003c\/li\u003e\n\u003cli\u003ePosition the probe pocket approximately at the middle height of the heated side of the hive.\u003c\/li\u003e\n\u003cli\u003ePlace the insulated side of the probe pocket toward the heating blanket and the sensing side toward the hive wall.\u003c\/li\u003e\n\u003cli\u003eKeep the probe pocket away from the hive entrance, upper entrance, and ventilation openings.\u003c\/li\u003e\n\u003cli\u003eWrap the heating blanket evenly around the exterior hive walls.\u003c\/li\u003e\n\u003cli\u003eKeep the probe pocket flat between the heating blanket and hive wall.\u003c\/li\u003e\n\u003cli\u003eSecure the blanket using the Velcro straps and buckle fasteners.\u003c\/li\u003e\n\u003cli\u003eConfirm the main entrance, upper entrance, and ventilation openings remain unobstructed.\u003c\/li\u003e\n\u003cli\u003eConnect the heating blanket plug to the thermostat controller.\u003c\/li\u003e\n\u003cli\u003ePlug the thermostat controller into a properly installed 120V AC outlet.\u003c\/li\u003e\n\u003cli\u003eSet a conservative starting temperature and monitor the hive response.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch4\u003eCorrect Probe Placement\u003c\/h4\u003e\n\u003cdiv class=\"yd-install-grid\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eMiddle Hive Height\u003c\/strong\u003e \u003cspan\u003e Position the probe pocket approximately at the middle height of the heated hive side. \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eSensing Side Toward Hive\u003c\/strong\u003e \u003cspan\u003e The sensing side must face the hive wall so the thermostat measures the hive-wall temperature. \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eInsulated Side Toward Blanket\u003c\/strong\u003e \u003cspan\u003e The insulated side should face the heating blanket to reduce direct heater influence on the reading. \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eKeep the Pocket Flat\u003c\/strong\u003e \u003cspan\u003e Make sure the probe pocket remains flat and does not fold, bunch, or shift after wrapping. \u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eDo Not Block\u003c\/h4\u003e\n\u003cdiv class=\"yd-alert-box\"\u003e\n\u003cp\u003eThe heating blanket must not cover the main hive entrance, upper entrance, ventilation openings, or any beekeeper-installed airflow path.\u003c\/p\u003e\n\u003cp\u003eThe hive must remain properly ventilated during both insulation-only and powered heating use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch4\u003ePower Connection\u003c\/h4\u003e\n\u003cdiv class=\"yd-check-grid\"\u003e\n\u003cspan\u003e Complete installation before connecting power \u003c\/span\u003e \u003cspan\u003e Confirm the supply is 120V AC \u003c\/span\u003e \u003cspan\u003e Connect the blanket to the thermostat first \u003c\/span\u003e \u003cspan\u003e Keep the thermostat dry and well ventilated \u003c\/span\u003e \u003cspan\u003e Do not use a damaged cord, probe, plug, or blanket \u003c\/span\u003e \u003cspan\u003e Disconnect power before adjustment, removal, or cleaning \u003c\/span\u003e\n\u003c\/div\u003e\n\u003ch4\u003eBasic Thermostat Operation\u003c\/h4\u003e\n\u003col\u003e\n\u003cli\u003ePress the power button to turn on the thermostat.\u003c\/li\u003e\n\u003cli\u003eUse the temperature-setting control to select the desired set temperature.\u003c\/li\u003e\n\u003cli\u003eConfirm the selected temperature.\u003c\/li\u003e\n\u003cli\u003eThe heater turns on when the detected temperature is below the set temperature.\u003c\/li\u003e\n\u003cli\u003eThe heater turns off when the detected temperature reaches the set temperature plus the configured upper limit.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch4\u003eExample of Thermostat Behavior\u003c\/h4\u003e\n\u003cp\u003eIf the set temperature is 59°F (15°C) and the upper limit is the default 9°F (5°C), heating turns on below 59°F and turns off at approximately 68°F (20°C).\u003c\/p\u003e\n\u003cp\u003eThis temperature difference reduces rapid on-and-off cycling. The upper limit can be adjusted through the thermostat’s advanced settings when necessary.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cdiv class=\"yd-product-section yd-faq-section\"\u003e\n\u003cdetails\u003e\n\u003csummary\u003eIs this designed to keep the entire hive warm?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eNo. It is designed to reduce heat loss and provide gentle supplemental heat during extreme cold. It should not be used to create warm or room-temperature conditions inside the hive.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan the blanket be used without connecting it to power?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eYes. The blanket can be used in insulation-only mode without electricity during mild or typical winter conditions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhen should I choose this product instead of the non-heated wrap?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eChoose this heating blanket when your hive may require controlled supplemental heat during extreme cold. For passive winter insulation without electricity, choose the \u003ca href=\"\/products\/winter-beehive-insulation-wrap\"\u003e \u003cstrong\u003eWinter Beehive Insulation Wrap\u003c\/strong\u003e \u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat temperature should I start with?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe manual recommends beginning around 50–59°F (10–15°C) and increasing only when necessary. Higher settings are usually unnecessary. Always consider local weather and colony conditions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhy does the heater continue operating above the set temperature?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe thermostat uses an adjustable upper limit to reduce rapid start-stop cycling. With the default 9°F (5°C) upper limit, the heater turns off when the measured temperature reaches approximately 9°F above the selected set temperature.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat is the maximum safe thermostat setting?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe set temperature must not exceed 82°F (28°C), and the set temperature plus the upper limit must not exceed 91°F (33°C).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhere should the thermostat probe be installed?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eInsert the probe into the included probe pocket and position it approximately at the middle height of the heated hive side. The sensing side should face the hive wall and the insulated side should face the heating blanket.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan the blanket cover the hive entrance or ventilation openings?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eNo. The main entrance, upper entrance, and all ventilation openings must remain completely unobstructed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan the heating blanket be left powered without inspection?\u003c\/summary\u003e\n\u003cdiv\u003e\n\u003cp\u003eRegular inspection is recommended. Check the hive temperature, moisture, entrances, ventilation, probe placement, blanket position, thermostat, cords, and electrical connections during winter use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003ch3\u003eGuides\u003c\/h3\u003e\n\u003cdiv class=\"yd-product-section\"\u003e\n\u003ch4\u003eBefore Powering On\u003c\/h4\u003e\n\u003cdiv class=\"yd-check-grid\"\u003e\n\u003cspan\u003e Confirm the hive is compatible with the wrap dimensions \u003c\/span\u003e \u003cspan\u003e Inspect the blanket, thermostat, probe, plugs, and cords \u003c\/span\u003e \u003cspan\u003e Insert the probe fully into the probe pocket \u003c\/span\u003e \u003cspan\u003e Position the sensing side against the hive wall \u003c\/span\u003e \u003cspan\u003e Keep all entrances and ventilation openings clear \u003c\/span\u003e \u003cspan\u003e Complete installation before connecting power \u003c\/span\u003e\n\u003c\/div\u003e\n\u003ch4\u003eRecommended Operating Approach\u003c\/h4\u003e\n\u003cdiv class=\"yd-scenario-grid\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eStart in Insulation Mode\u003c\/strong\u003e \u003cspan\u003e Use the blanket without power when passive insulation is sufficient for the weather conditions. \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eUse Heat Only When Needed\u003c\/strong\u003e \u003cspan\u003e Activate supplemental heating only during extreme cold or when your hive-management plan requires it. \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eBegin With a Low Setting\u003c\/strong\u003e \u003cspan\u003e Start around 50–59°F (10–15°C) and increase conservatively only when necessary. \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eMonitor the Hive\u003c\/strong\u003e \u003cspan\u003e Regularly check ventilation, moisture, probe placement, measured temperature, and colony conditions. \u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eThermostat Advanced Settings\u003c\/h4\u003e\n\u003cp\u003eThe thermostat includes optional advanced settings for temperature-unit selection, sensor calibration, timer operation, upper-limit adjustment, and factory reset.\u003c\/p\u003e\n\u003cp\u003eThe basic temperature controls are sufficient for normal operation. Advanced settings should only be changed when a specific adjustment is required.\u003c\/p\u003e\n\u003ch4\u003eAdvanced Setting Functions\u003c\/h4\u003e\n\u003ctable class=\"yd-spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSetting\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e°F \/ °C Selection\u003c\/td\u003e\n\u003ctd\u003eChanges the temperature display between Fahrenheit and Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Calibration\u003c\/td\u003e\n\u003ctd\u003eAdjusts the displayed temperature when verified against a reliable reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimer Function\u003c\/td\u003e\n\u003ctd\u003eSets how long the thermostat remains active before switching off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpper Limit\u003c\/td\u003e\n\u003ctd\u003eAdjusts the temperature difference between heater turn-on and turn-off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactory Reset\u003c\/td\u003e\n\u003ctd\u003eRestores the thermostat to its original default settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eCleaning \u0026amp; Storage\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect power and allow the blanket to cool completely before cleaning.\u003c\/li\u003e\n\u003cli\u003eRemove the heating blanket when it is not in use.\u003c\/li\u003e\n\u003cli\u003eClean gently with a damp cloth.\u003c\/li\u003e\n\u003cli\u003eDo not use chemical or corrosive cleaning agents.\u003c\/li\u003e\n\u003cli\u003eDo not pull the blanket roughly or damage the internal heating elements.\u003c\/li\u003e\n\u003cli\u003eAvoid sharp folding, puncturing, crushing, or contact with sharp objects.\u003c\/li\u003e\n\u003cli\u003eStore in a cool, dry place away from direct sunlight, moisture, excessive heat, and sharp objects.\u003c\/li\u003e\n\u003cli\u003eInspect the Velcro straps, buckle fasteners, probe, cord, and controller before reuse.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eThermostat Safety\u003c\/h4\u003e\n\u003cdiv class=\"yd-alert-box\"\u003e\n\u003cp\u003eDo not connect a total load exceeding 1200W or 10A to the thermostat controller.\u003c\/p\u003e\n\u003cp\u003eKeep the controller dry and well ventilated. Do not disassemble, modify, or attempt unauthorized repairs. Keep the system out of reach of children and pets.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch4\u003eTechnical Support\u003c\/h4\u003e\n\u003cp\u003eFor help confirming compatibility or selecting between the heated and non-heated hive wraps, contact YeloDeer support with your hive dimensions, local winter conditions, and intended use.\u003c\/p\u003e\n\u003cp\u003eEmail: \u003ca href=\"mailto:yelodeer@yelodeer.com\"\u003e \u003cstrong\u003eyelodeer@yelodeer.com\u003c\/strong\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"YeloDeer","offers":[{"title":"Default Title","offer_id":45375811420401,"sku":"Y-Bee-H","price":85.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0701\/2836\/9905\/files\/BeehiveHeatingBlanket_3.jpg?v=1787020909","url":"https:\/\/yelodeer.com\/products\/beehive-heating-blanket","provider":"YeloDeer","version":"1.0","type":"link"}